Section 3 Engineering Guidelines
Name
A
RS-232
B
Test
C
T1A - T1D
D
Alarm
E
DC Power
F
Fuse
G
Antenna
H
Ground Lug
1
Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.
RS-232 Connection (DB-25) — Terminal Use
The
connector provides a female DB-25 terminal connection (wired as a DCE interface), which is
RS-232
used for terminal access to the TRACER 4106/4206 system. The
functions:
Accepts EIA-232 input from a PC or terminal for controlling the TRACER 4106/4206 system
Operates at 9600 bps
Table 2 shows the pinout. Wiring diagrams for connecting to the
applications) are provided following the pinout.
PIN
1, 7
2
3
4
5
6
8
9-19
20
21
22
23-25
28
Table 1. Rear Panel Description
Connector
Description
DB-25 (female)
VT100 terminal (or PC with terminal emulation software)
connection
1/4" bantam
Factory test connection
RJ-48C
T1 device connection
Terminal block
External alarm monitoring system connection
Terminal block
21-60 VDC power source connection
N/A
2 A, 250 V, 2 inch slow-blo fuse
N-Type
Antenna feedline cable connection
N/A
Earth ground connection
Table 2. RS-232 Connection Pinout
NAME
GND
Ground
TX
Transmit
RX
Receive
RTS
Request To Send
CTS
Clear To Send
DSR
Data Set Ready (Modem Control Only)
CD
Carrier Detect
Unused
DTR
Data Terminal Ready (Modem Control Only)
Unused
RI
Ring Indicator
Unused
© 2004 ADTRAN, Inc.
TRACER 4106/4206 System Manual
1
port provides the following
RS-232
connector (for various
RS-232
DESCRIPTION
612804206L2-1A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracer 4206 plan aTracer 4106Tracer 4206

Table of Contents