Section 3 Engineering Guidelines
Name
A
RS-232
B
Test
C
T1A - T1D
D
Alarm
E
DC Power
F
Fuse
G
Antenna
H
Ground Lug
1
Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.
RS-232 Connection (DB-25) — Terminal Use
The
connector provides a female DB-25 terminal connection (wired as a DCE interface), which is
RS-232
used for terminal access to the TRACER 4106/4206 system. The
functions:
•
Accepts EIA-232 input from a PC or terminal for controlling the TRACER 4106/4206 system
•
Operates at 9600 bps
Table 2 shows the pinout. Wiring diagrams for connecting to the
applications) are provided following the pinout.
PIN
1, 7
2
3
4
5
6
8
9-19
20
21
22
23-25
28
Table 1. Rear Panel Description
Connector
Description
DB-25 (female)
VT100 terminal (or PC with terminal emulation software)
connection
1/4" bantam
Factory test connection
RJ-48C
T1 device connection
Terminal block
External alarm monitoring system connection
Terminal block
21-60 VDC power source connection
N/A
2 A, 250 V, 2 inch slow-blo fuse
N-Type
Antenna feedline cable connection
N/A
Earth ground connection
Table 2. RS-232 Connection Pinout
NAME
GND
Ground
TX
Transmit
RX
Receive
RTS
Request To Send
CTS
Clear To Send
DSR
Data Set Ready (Modem Control Only)
CD
Carrier Detect
—
Unused
DTR
Data Terminal Ready (Modem Control Only)
—
Unused
RI
Ring Indicator
—
Unused
© 2004 ADTRAN, Inc.
TRACER 4106/4206 System Manual
1
port provides the following
RS-232
connector (for various
RS-232
DESCRIPTION
612804206L2-1A