T1X Status/Configuration/Loopback - ADTRAN TRACER 4106 Plan A System Manual

Adtran network device system manual
Table of Contents

Advertisement

TRACER 4106/4206 System Manual
>T1
S
/C
X
TATUS
ONFIGURATION
The following menus for the T1x Status/Configuration/Loopback apply to all four
available T1 interfaces (A through D).
Figure 8 shows the T1x Status/Configuration/Loopback menu page, which displays a real-time graphical
representation for the T1x link using data from both the local and remote TRACER 4106/4206 units. T1x
operational configuration parameters and testing functions are configured from this menu.
>T1
S
/C
X
TATUS
ONFIGURATION
Displays any active alarms on the T1 link (reported from both the local and remote TRACER 4106/4206
units). These alarms include Red, Blue/AIS, Yellow, LOS, and bipolar violations (
describes these alarms. See Section 6, Troubleshooting Guide, for more information on these alarms.
RED
Activates when a local facility failure occurs.
BLUE/AIS
Activates when an incoming remote alarm is received from a connected T1 device. An AIS
signal is an unframed All One signal that replaces the normal traffic signal
YEL
Activates when an incoming remote alarm is received from the T1 device indicating that a
failure has occurred in the received direction.
LOS
Activates when no T1 signal is present from the connected T1 equipment. LOS is
activated after receiving 192 consecutive zeros.
BPV
Activates when the incoming T1 stream presents bipolar violations (BPVs).
612804206L2-1A
/L
OOPBACK
Figure 8. T1x Status/Configuration/Loopback
/L
> T1
OOPBACK
Table 2. T1 Interface Alarms
© 2004 ADTRAN, Inc.
Section 5 User Interface Guide
I
A
X
NTERFACE
LARMS
BPV
). Table 2 briefly
51