Summary of Contents for Rice Lake 880 Performance Series
Page 1
880 Performance Series ™ Controller/Indicator Version 4.01 Operation Manual March 10, 2021 PN 152240 Rev D...
Page 2
All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
Setup Menu ..........18 Technical training seminars are available through Rice Lake Weighing Systems.
Page 4
3.1 Error Messages ..........31 Compliance ................32 Specifications ................33 Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost. Visit www.ricelake.com/webinars. Visit our website...
Information contained within this manual is exclusively for units with CPU IMPORTANT board, PN 175109 (blue in color). The 880 Performance Series Technical Manual (PN 158387) is referred to in this manual is available online. Manuals and additional resources are available on the Rice Lake Weighing Systems website at www.ricelake.com...
General Safety Do not operate or work on this equipment unless this manual has been read and all instructions are understood. Contact any Rice Lake Weighing Systems dealer for replacement manuals. WARNING Failure to heed may result in serious injury or death.
• View or clear the accumulator value • Change setpoint values • View the current tare value • Enter Setup mode (if audit trail is enabled) rmation. 880 Performance Series Technical Manual (PN 158387) for more info Visit our website www.RiceLake.com...
Page 10
880 Performance Series Controller/Indicator Item No. Function Sets the current gross weight to zero; Used to navigate to other menus or to select another digit when editing a value Sends an on-demand print format to a communications port, provided the conditions for standstill are met;...
880 Performance Series Controller/Indicator 1.6.3 Alphanumeric Entry Procedure Use the following scheme for alphanumeric entry when using the five-button keypad. Level 1 Level 1 Parameter Parameter Level 2 Level 2 Parameter Parameter Display first 6 Scroll left in format string.
880 Performance Series Controller/Indicator 1.7.6 Preset Tare (Keyed Tare) Note Tare mode must be set to keyed or both for the preset tare feature to function. 1. With the scale empty and zero weight on the display, press . 000000 displays TARE with the focused digit flashing.
7. Select the type by pressing to desired setting then press to set the value. For complete list of settings see the 880 Performance Series Technical Manual (PN 158387) for more information. to return to Weigh mode. 8. When all settings have been made, press MENU Setpoints are now accessible from the front panel menu.
880 Performance Series Controller/Indicator 1.7.11 Display or Edit Setpoint Value . Audit displays. 1. Press MENU until Setpts displays. 2. Press 3. Press and the first available setpoint number displays. 4. Press to toggle through each setpoint which is operator accessible.
Weigh mode. MENU If there is no tare in the system, the value displayed is zero and the Gross and Net LED turn off. See the 880 Performance Series Technical Manual (PN 158387) for more information. Visit our website www.RiceLake.com...
When the indicator is placed in Configuration mode, SCALE displays. The SCALE menu is the first of eight top-level menus used for configuring the indicator. Detailed descriptions of these menus are given in the 880 Performance Series Technical Manual (PN 158387). When configuration is complete, return to the SCALE menu and press the (ZERO) key to exit Setup mode.
Configuration using the menus is described in the 880 Performance Series Technical Manual (PN 158387). Configuration using the EDP port can be accomplished using either the EDP command set described in the 880 Performance Series Technical Manual (PN 158387) or Version 3.0 or later of the Revolution configuration utility.
880 Performance Series Controller/Indicator Menu Structures and Parameter Descriptions The following sections provide graphic representations of the 880 menu structures. In the actual menu structure, the settings chosen under each parameter are arranged horizontally. To save page space, menu settings display in vertical columns. The factory default setting display at the top of each column and is bold.
880 Performance Series Controller/Indicator 2.2.4 Format Menu ..SETUP T & D INFO If SPLIT = OFF ..SCALE FEATUR PORTS ..FORMAT ZTRKBN ZRANGE DSPDIV UNITS DECPNT DSPDIV UNITS DECPNT 888888 88888.8 888880 888888 8.88888 888880 88.8888...
880 Performance Series Controller/Indicator 2.2.6 Feature Menu ..SETUP T & D INFO ..PORTS PFORMT FEATUR REGION CONSC# PASSWD Section 2.2.7 000000 CURVAL RESVAL USER SETUP on page 23 KEYLCK LATUDE ELEVAT IRITE LOCALE 0-90 -9999 to +9999...
880 Performance Series Controller/Indicator 2.2.9 COM and USBCOM Menus ..SETUP T & D INFO ..PORTS PFORMT SETPTS ..USBCOM SERIAL ETHNET CHAN 2 CHAN 1 Same menu structure as COM with DUPLEX added. SFMT TRIGGE TERMIN...
880 Performance Series Controller/Indicator 2.2.12 Print Format Menu ..SETUP T & D INFO ..PFORMT SETPTS DIGIO GFMT NFMT ACCFMT SPFMT HDRFMT format PORT format USBCOM CHAN 1 CHAN 2 ETH-S ETH-C USBMEM Figure 2-14. Print Format Menu Structure 2.2.13 Setpoint Menu...
Page 32
880 Performance Series Controller/Indicator Setpoint Menu – Layout B PAUSE, DELAY, WAITSS, COUNTR, AUTJOG CLRACM CLRTAR PSHACM PSHPRT PSHTAR VALUE number ONQUIE WAITSS DELAY, WAITSS and AUTJOG setpoints only. ACCESS NAME SLOT DIGOUT SENSE BRANCH NONE 6ALPHA NORMAL BIT1-BITx SLOT 0...
880 Performance Series Controller/Indicator 2.2.15 Analog Output Menu The ALGOUT menu is used only if the analog output option is installed. If the analog output option is installed, configure all other indicator functions and calibrate the indicator before configuring the analog output. See Technical/Service Manual for analog output calibration procedures.
Page 38
880 Performance Series Controller/Indicator Dimensions (W x H x D) Panel 6'' x 4'' x 4.95'' (152 mm x 102 mm x 126 mm) Universal 9.87'' x 9.38'' x 4.33'' (251 mm x 238 mm x 110 mm) Weight Panel 2.5 lb (1.2 kg)
Page 40
Specifications subject to change without notice. Rice Lake Weighing Systems is an ISO 9001 registered company. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319...
Need help?
Do you have a question about the 880 Performance Series and is the answer not in the manual?
Questions and answers