Cover the workstation with approved static-shielding material.
●
Use a wrist strap connected to a properly grounded work surface and use properly grounded tools and
●
equipment.
Use conductive field service tools, such as cutters, screw drivers, and vacuums.
●
When fixtures must directly contact dissipative surfaces, use fixtures made only of static-safe materials.
●
●
Keep the work area free of nonconductive materials, such as ordinary plastic assembly aids
and polystyrene foam.
Handle ESD-sensitive components, parts, and assemblies by the case or PCM laminate. Handle these items
●
only at static-free workstations.
Avoid contact with pins, leads, or circuitry.
●
Turn off power and input signals before inserting or removing connectors or test equipment.
●
ENWW
Service considerations