The unit must not be setup in a fire-endangered opera-
ting site!
According to DIN VDE 0100-482 (VDE 0100 Part 482),
this is:
1997-08
Rooms or locations in rooms or in the open, in which, with
respect to the local and operational circumstances, the
danger exists that highly inflammable materials could
come so close to the electrical equipment at such hazar-
dous levels that the higher temperatures of this electrical
equipment or electric arcing create a fire hazard.
This includes: Working, dry and storage rooms or sections
of rooms, as well as similar outside locations, such as
paper, textile and wood processing operations, hay, straw,
jute or flax storage yards.
- According to BGR 500, chapter 2.35 or local regulations
for operation and maintenance. (qualified staff)
2.4

Transport

The Refrigeration unit must be transported in its opera-
ting position due to oil in the compressor. For possible
further transport, only the original packaging may be
used.
2.5

Delivery condition for Wall-hanging units

The Wall-hanging unit is delivered in a carton, operatio-
nally ready and wired for immediate plug-in.
2.6

Delivery condition for Split units

The Split unit is delivered in a carton and wired for
immediate plug-in.
General notice (liability): the details of this technical documents serve for description. Consents regarding the availability of certain features or
regarding a certain purpose always require a special written agreement.
Page No. 4-GB
2.7

Unpacking and handling

- Prior to and during the unpacking of the Refrigeration
unit, a visual inspection should be made in to deter-
mine whether possible damage has occurred during
transport.
- Please pay attention to loose parts, dents, scratches
visible oil loss, etc.
- Before disposing of the packing material, a check of it
should be made to ensure that no loose parts are hid-
den in it.
- In order to process warranty claims, please provide an
exact description of the deficiency (with picture if pos-
sible), as well as information as to unit model designa-
tion and serial number.
- In order to protect the unit from damage, it must only
be transported in its operating position. It must be
ensured that the evaporator and condenser units have
not been damaged. Non-compliance will result in for-
feiture of the warranty entitlement.
2.8

Energy conservation

Direct sunlight will raise the consumption of electricity.
Avoid any unnecessary or too lengthy opening of the
door.
Monitor the storage temperature.
Regularly clean the Refrigeration unit. A clean unit saves
energy and has a longer service life.
Observe cleaning intervals (see Chapter "Cleaning and
maintenance of the Refrigeration unit"). Regular mainte-
nance increases the service life.