Viessmann CS Installation And Operating Instructions Manual page 25

Refrigeration units with sd control unit
Table of Contents

Advertisement

Parameter Description
Unit model
CT = Normal refrigeration ceiling unit
P50
FT = Deep-freezer ceiling unit
CS = Normal refrigeration wall-hanging unit
FS = Deep-freezer wall-hanging unit
P51
Reset to factory settings (P = 78)
P52
Compressor run time, last cycle [hours]
P53
Compressor run time, last cycle [minutes]
P54
Compressor run time, second to last cycle [hours]
P55
Compressor run time, second to last cycle [minutes]
P56
Compressor run time, third to last cycle [hours]
P57
Compressor run time, third to last cycle [minutes]
P58
Compressor run time, forth to last cycle [hours]
P59
Compressor run time, forth to last cycle [minutes]
P60
Compressor standing time, last cycle [hours]
P61
Compressor standing time, last cycle [minutes]
P62
Compressor standing time, second to last cycle [hours]
P63
Compressor standing time, second to last cycle [minutes]
P64
Compressor standing time, third to last cycle [hours]
P65
Compressor standing time, third to last cycle [minutes]
P66
Compressor standing time, forth to last cycle [hours]
P67
Compressor standing time, forth to last cycle [minutes]
P68
Compressor average run time, 4 cycles [hours]
P69
Compressor average run time, 4 cycles [minutes]
P70
Compressor average standing time, 4 cycles [hours]
P71
Compressor average standing time, 4 cycles [minutes]
P72
Compressor switch-on count (xxyy00-xxyy99)
P73
Compressor switch-on count (xx00zz-xx99zz)
P74
Compressor switch-on count (00yyzz-99yyzz)
P75
Switch-on count after restart (xxyy00-xxyy99)
P76
Switch-on count after restart (xx00zz-xx99zz)
P77
Switch-on count after restart (00yyzz-99yyzz)
P78
Pressostat fault count (xxyy00-xxyy99)
P79
Pressostat fault count (xx00zz-xx99zz)
P80
Pressostat fault count (00yyzz-99yyzz)
P81
Compressor run time after end of defrosting process
P82
Compressor run time after end of defrosting process
P83
Current bus address
P84
Cont. defrosting pause time or pause-time [hours]
P85
Cont. defrosting pause time or pause-time [minutes]
General notice (liability): the details of this technical documents serve for description. Consents regarding the availability of certain features or
regarding a certain purpose always require a special written agreement.
Page No. 25-GB
8.5.1
Altered
Unit
ange
values
C.t., F.t.,
C.S., F.S.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
hrs.
min.
We reserve the right to make technical changes!