Newcom.sys Parameters - Brainboxes CC-431 Hardware Manual

Brainboxes cc-431 pci cards: hardware guide
Table of Contents

Advertisement

Software Configuration

NEWCOM.SYS Parameters.

The NewCOM.SYS device driver included with the PCI 3 Port RS232
driver software is used to set up the card in DOS and has the
following syntax:
NEWCOM.SYS /A port address, /I IRQ,range /B number buffer
/S buffer /H hardware handshake
Where /A port address specifies COM port number followed by a
hexadecimal address in the form /Ax,y where x is COM
port range and y is I/O address.
/I IRQ, range specifies card interrupt and COM port range. The
COM port range specifies the COM port(s). Range may be a
single port OR a range of ports.
/B number buffer is used to set the number of pairs of
buffers to be allocated to ports and is a decimal number in
the range 1-maxport.
/S buffer Set size of all buffers in bytes, buffer is rounded
to the nearest power of 2 and must be a decimal number in
the range 32 to 32768. For any serial port opened two
buffers of size buffer are allocated, one for input and the
other for output.
/H hardware handshake selects which hardware handshake
type to use on the specified ports. This is used in the
following manner: /H range, hs where range specifies the
COM port or ports and hs selects handshake type.
Handshake types available are:
Type 0
Chapter 3 Page 32
RS232 DTR/CTS - The PC only transmits
when CTS is input true. When the PC is able to
receive its sets DTR output true. The DSR and
PCI 3 Port RS232