VAT 642 Series Installation, Operating, & Maintenance Instructions page 43

Control gate valve with logic interface
Table of Contents

Advertisement

Series 642
1.1.1.2
Pressure control parameter
• Open CV or CPA
• Go to «Tools» > «Terminal» and send setup command s:02 according
to application needs. (possibility of adjustment see below)
Set
Get
This command selects pressure control parameter.
a
bb
c
For details (commands etc.), see next tables.
Remark: Each pressure control algorithm has its own parameters. That
means the adjustment of a e.g. adaptive downstream parameter (e.g.
Ramp Time "Adaptive downstream") doesn't influence one of the other
Ramp time parameter of other pressure control algorithms and vice
versa.
1.1.1.3
Overview parameter number
Parameter
SENSOR
DELAY
RAMP TIME
RAMP MODE
CONTROL
DIRECTION
P-GAIN (for A =
GAIN FACTOR)
I-GAIN
existent for this pressure controller
× not used for this pressure controller
605403ED
Local operation:
('Control View' or 'Control Performance Analyzer')
Command
s:02abbc
configure pressure control
parameters
i:02abbc
get pressure control parameters
pressure controller (one digit) see table:
parameter number (two digits) see table: "Overview parameter
number"
parameter value using data type "unsigned integer" or "floating
point" (dependend on the corresponding data type)
bb
Parameter
number
00
01
02
03
04
05
Edition 2017-11-24
INSTALLATION
Acknowledgement
(within 10ms after reception of
command)
Describtion
i:02abbc
a = A
a = B
(adaptive
(fixed 1
pressure
pressure
controller)
controller)
×
×
×
Remote operation:
It is not possible with remote
operation.
a = C
a = D
(fixed 2
(soft pump
pressure
pressure
controller)
controller)
×
×
×
×
43/94