ADJUSTMENTS AND REPLACEMENTS
Section 6: Electrical
Removing the AUTOTRANSFORMER T1 or EMI LINE FILTER
AUTOTRANSFORMER
28
EMI LINE FILTER
H104_0580CCA
H104_0580CA
[1] De-energize the PROCESSOR.
[2] For easier access, remove the BACK ACCESS
PANEL and the MULTILOADER BULKHEAD
PANEL.
[3] For more play in the HOSES, place the
MULTILOADER BULKHEAD PANEL inside the
MULTILOADER.
[4] Fully extend the PROCESSOR from the
MULTILOADER.
[5] Remove the FEED END SAFETY COVER.
[6] For easier access to the AUTOTRANSFORMER
and LINE FILTER, push the PROCESSOR back
into the MULTILOADER.
[7] Working from the back of the MULTILOADER,
remove the desired part. Record the position of
the wires for the installation of the new part.
Warning
You must install all SAFETY COVERS which were
removed for access.
[8] Install the COVERS and PANELS. See
H104_0585GCA
H104_0585GC
Page
5.
MULTILOADER
BULKHEAD PANEL
BACK ACCESS PANEL
28JAN98 – 7C8285