2.0) BROODER SPECIFICATIONS

INPUT RATING
GAS SUPPLY PRESSURE
MANIFOLD PRESSURE
ORIFICE SIZE
(MAIN BURNER)
ORIFICE SIZE
(VALVE OUTLET)
MOUNTING HEIGHT
BROODER SPACING
BROODER SIZE
WEIGHT
VENTILATION REQUIRED
GAS CONSUMPTION
ELECTRICAL SUPPLY

3.0) BROODER CONTROL DESCRIPTION

Brooder Control No. 5 is designed for single or multi-zone installations using one or more thermostats. The
burner is controlled with a Direct Spark Ignition (DSI) switch, which is designed to provide 100 percent gas
shut off of the main valve in the event that the main burner flame is not sensed.
40,000 Btu/hr (11.72 kW)
Propane Gas:
40,000 Btu/hr (11.72 kW)
Natural Gas:
40,000 Btu/hr (11.72 kW)
Propane/Butane Mix Gas
5.0 PSIG (345 mbar) MAX
Propane Gas:
5.0 PSIG (345 mbar) MAX
Natural Gas:
5.0 PSIG (345 mbar) MAX
Propane/Butane Mix Gas
5 PSIG (345 mbar)
Propane Gas:
5 PSIG (345 mbar))
Natural Gas:
5 PSIG (345 mbar)
Propane/Butane Mix Gas
5/64" (.0781")
Propane Gas:
3.1mm (.1220")
Natural Gas:
1.8mm (.0709")
Propane/Butane Mix Gas
#61 (.0390")
Propane Gas:
1.2mm (.0470")
Natural Gas:
#64 (.0360")
Propane/Butane Mix Gas
Recommended - 72" (1830mm)
25' – 40' (7.6m – 12.2m)
35" (890mm)
Canopy Diameter:
13.75" (349mm)
Brooder Height:
21.5 lbs (10 kg)
Assembled Brooder:
160 CFM (272 m
Per Brooder:
0.43 GPH (1.63 L/hr)
Propane Gas:
0.40 Therm (42.2 MJ/Hr)
Natural Gas:
0.43 GPH (1.63 L/Hr)
Propane/Butane Mix Gas
120 VAC, 1 PH, 60Hz
–2–
5.0 PSIG (345 mbar) MIN
5.0 PSIG (345 mbar) MIN
5.0 PSIG (345 mbar) MIN
/hr)
3
Form No. 43539510
May 2020