STEP 10: NATURAL GAS UNITS REQUIRE USE OF AN AIR RESTRICTOR CUP. Place the cup on the burner
manifold tubing before attaching the gas control as shown above in STEP 7. Engage the slots from the cup
with the hemmed flanges of the burner. Engage the round bosses of the cup with the holes in the burner.
WARNING: ONCE THE BROODER IS ASSEMBLED AND BEFORE IT IS FIRST FIRED, YOU MUST CHECK FOR
GAS LEAKS! USE A SOAP AND WATER SOLUTION AND APPLY AT ORIFICE FITTING AND FIELD CONNECTIONS
TO THE GAS VALVE.

4.1) GAS VALVE WIRE CONNECTIONS

STEP 1: Flip the brooder over and Insert the red and green/yellow wire leads from the gas valve through the
cable gland of the ignition control box. See below.
STEP 2: Connect both red wires of the gas valve to the terminals marked V1 and V2 of the ignition module.
Note: The wires emerging from the coil must point down.
STEP 3: Connect the green/yellow wire of the gas valve to the ground screw
Refer to the wiring diagrams located in Section 8, Electrical Connections for the incoming power connections.
Re-tighten the cable gland after all wiring connections are complete.
Form No. 43539510
May 2020
–9–

Advertisement