Figure 2-13 Webui Out Of Service Indications - Siemens WEBUI Quick Manual

Gcp web user interface
Table of Contents

Advertisement

SYSTEM VIEW
Select OK if required. The WebUI will now show: GCP Out of Service as shown in Figure 2-13 on the
left. The System View will show the GCP OOS icon flashing between blue and white.
The track module will also display the message GOFS on its four-character display. The maintenance
call output on the GCP will turn off, causing the maintenance call lamp to go off, if it is wired. The
maintenance call light is illuminated when running properly, if it goes dark, that indicates a problem at the
location.
To return the GCP to service, if OOS Control is set to Display+OOS IPS, de-energize the track OOS
input on the track module.
If OOS Control is set to Display, use the WebUI module and select the Put GCP Back in Service
button shown in Figure 2-13 above. (This requires local user presence - Section 6.1.5.1).
When a GCP is OOS but the island remains in service, the crossing will
activate when the island is occupied.
Putting the GCP back in service will also put the island back in service if it
was out of service.
If the OOS Control is set to Display+OOS IPs and the Trk OOS Input is still energized, performing the
above step will put the track back in service; however, the maintenance lamp call will remain off while the
Trk OOS Input is still energized. Similarly, if the out of service timer expires and the Trk OOS Input is still
energized, the maintenance call lamp will remain off.
SIG-QG-20-02
Version : A.2

Figure 2-13 WebUI Out of Service Indications

2-10
NOTE
NOTE
JANUARY 2021