Figure 2-5 Detail View Gcp 4000/5000 - Siemens WEBUI Quick Manual

Gcp web user interface
Table of Contents

Advertisement

SYSTEM VIEW
2.1.1 Track – Detail View
The track detail view shows more detailed information about the track module. This screen is primarily
used to see the information shown in Figure 2-6 (highlighted with yellow boxes) as this is not available
elsewhere on the WebUI:
Check EZ – value of EZ on the check wires,
Island Z Level – the island signal level, where 100 or lower indicates occupancy,
Track Check Number (TCN) and date and time it was last changed.
The Island Z level represents the normalized signal level on the island. When the value is below 100 the
island becomes occupied, the island will start its pickup delay timer running when the Z level goes back
over 110. The display does not show values over 250, even though the island level will generally be
much higher.
The track detail screen also shows the user the EZ/EX limits information consisting of:
the highest EZ value the track has recorded since this screen was last reset and the EX value at
that time. The time/date this occurred is shown.
the lowest EX value the track has recorded since this screen was last reset and the EZ value at
that time. The time/date this occurred is shown.
SIG-QG-20-02
Version : A.2

Figure 2-5 Detail View GCP 4000/5000