ELECTRICAL CONNECTION

The network voltage must conform to the voltage indicated on the tool name
plate. Under no circumstances should the tool be used when the power supply
cable is damaged. A damaged cable must be replaced immediately by an
authorized Customer Service Center. Do not try to repair the damaged cable
yourself. The use of damaged power cables can lead to an electric shock.
WARNING: Never operate a damaged machine. Always tag a damaged machine
and take it out of service until repairs can be made.
WARNING: These machines are equipped with a Portable Residual Current
Device (PRCD) also known as a Ground Fault
Circuit Interrupter (GFCI). Always use this
device whenever using the machine to reduce
the risk of shock hazards. Always position the
PRCD as close as possible to the power
source. Test and reset the PRCD device before
each use. Press the "Test" button to test.
Press the "Reset" button to energize the circuit to the machine.
Note: PRCD (GFCI) appearances vary according to the requirements of various
regions. Photos for reference only
WARNING: Always connect the plug into the wall socket with a drip loop. If the
cable leads downward directly into the wall socket, any water on the cable could
run into the socket, causing a hazard.
10
14 in. Electric Wet/Dry Concrete Saw
220-
50 (15m)
240
Minimum gauge for cord (AWG)
12
(4.0mm2)
100 (30m)
12
(4.0mm)
For technical questions call 1-800-665-8685
150
300
(50m)
(100m)
Not recommended