Casio DT-X8 Series Software Manual page 55

Hide thumbs Also See for DT-X8 Series:
Table of Contents

Advertisement

2.2.6 Expanded Features
Scan Width Control
If the laser emits on several bar codes located near each other, scanning may fail. By narrowing
the laser beam emission width, scanning can be focused onto only one bar code, not onto the other
one located near by. The laser beam emission width can be set to one of the four modes as shown
in following figure. The Laser Scanner Library can be used to set it. The default is "No control on
laser beam emission width".
• No control on laser beam emission width (default)
• Wide
• Standard
• Narrow
照射幅制御なし
No laser width control
No control
Figure 2-9
The setting values are stored in EEPROM, and read out at time of resetting. Laser calibration (see
note below) can be used to adjust each setting value for the laser beam emission width. The setting
values adjusted must be registered in the registry. The values in the registry will have the priority.
Note:
Each scanner module integrated in the terminal has an individual performance different from
others. To minimize this characteristic difference, the laser calibration must be performed on each
terminal using a dedicated reference bar code.
The functions of the Laser Scanner Library relevant to the "Scan Width Control" are as follows.
OBRSetSwingAngle
OBRGetSwingAngle : Retrieves the status of swing angle control mode.
Wide
: Sets up swing angle control mode.
55
Standard
Narrow

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dt-x8-10eDt-x8-10c-cnDt-x8-20eDt-x8-20c-cn

Table of Contents