Configuration File - Casio DT-X8 Series Software Manual

Hide thumbs Also See for DT-X8 Series:
Table of Contents

Advertisement

Configuration File

The various setting values can be stored in a file and resumed. The setting file storage location and
its name are "\Documents and Settings\System Settings\OBRDRV.ini". If there is no such the
setting file, the default values are used to initiate the scanning.
Table 2.47
Symbol
Parameter
ogy
READCODE
CODE39_MIN
CODE39_MAX
CODE39_OUTFORMAT
CODE39_CHKD
CODE39_CHKCH
Continue.
Description
Range
Enable or disable
scanning the
symbologies.
(note 1)
16384
32768
65536
Valid minimum digits
Valid maximum digits
Output format
Check digit calculation
Check character output
60
Default
1
131071
1:
2
2:
4
4:
8
8:
16
16:
32
32:
64
64:
128
128:
256
256:
512
512:
1024
1024:
2048
2048:
4096
4096:
8192
8192:
16384:
32768
65536
2
2
52
52
0
0
0:
With start and stop
characters
1
1:
Without start and stop
characters
2
2:
With Full ASCII conversion
With start and stop
characters
3
3:
With Full ASCII conversion.
Without start and stop
characters.
0
0
0:
Disable
1
1:
Enable
0
1
0:
Disable
1
1:
Enable
Setting
Enable Code39
Enable NW-7
Enable WPC Addon
Enable WPC
Enable UPC-E Addon
Enable UPC-E
Enable IDF
Enable ITF
Enable Code93
Enable Code128
Enable MSI
Enable IATA
Enable GS1 DataBar
Omnidirectional.
Enable GS1 DataBar
Limited.
Enable GS1 DataBar
Expanded.
Enable GS1 DataBar
Stacked.
Enable GS1 DataBar
Expanded Stacked.

Advertisement

Table of Contents
loading

This manual is also suitable for: