Casio DT-X8 Series Software Manual page 176

Hide thumbs Also See for DT-X8 Series:
Table of Contents

Advertisement

and
Read operation
These tabs are to set up the following parameters related to scanning bar code symbologies.
Choose a mode you wish to set up in each pull-down menu.
Mode selection on Read operation Tab
Continuous read or Single read
Swing Angle Wide, Swing Angle Middle, or Swing Angle Narrow (Note 1)
Enable Laser Focus or Disable Laser Focus (Note 2)
Output OBR buffer or Output Clipboard or Output Keyboard
Disable termination code or Termination code CR, LF, CR, LF, TAB
Selection of the decoding level, "Normal" or "High" or "Steady".
Normal read or Gradation read (Note 3)
With or without filter, or with hard filter/with soft (Note 4)
Mode selection on Read operation 2 Tab
Selection of the gain, Gain Mode0 to Mode3 or Auto.
Learning Decode ON or Learning Decode OFF
Notes:
1. The function is named "Scan Width Control" function.
2. The function is named "Scan Verification Beam" function.
3. "Gradation read" is named "Multi-step read".
4. Selection on "Without filter" or "With soft filter" is valid. Other selections in the pull-down
menu do not effect because the hardware filter is not integrated in the terminal.
Figure 3-53
Read operation 2 Tabs
Figure 3-54