To find Fluid Outlet Pressure (psi/bar) at a specific fluid flow (gpm/lpm) and operating air pressure (psi/bar):
1. Locate desired fluid flow along bottom of chart.
2. Follow vertical line up to point of intersection with selected fluid outlet pressure curve.
2. Align point on curve with vertical scale on left side of chart to read fluid outlet pressure.
900
(62.1)
800
(55.2)
700
(48.3)
600
(41.4)
500
(34.5)
400
(27.6)
300
(20.7)
200
(13.8)
100
(6.90)
To find Pump Air Consumption (scfm or m
1. Locate desired fluid flow along bottom of chart.
2. Follow vertical line up to point of intersection with selected air consumption curve.
2. Align point on curve with vertical scale on left side of chart to read air consumption.
90
(2.52)
80
(2.24)
70
(1.96)
60
(1.68)
50
(1.40)
40
(1.12)
30
(0.84)
20
(0.56)
10
(0.28)
Performance Charts
Test Conditions: Pump tested with AW-32 oil at 75_ F (24_ C)
A
B
C
D
0
0
2
(7.57)
3
/min) at a specific fluid flow (gpm/lpm) and operating air pressure (bar/psi):
Test Conditions: Pump tested with AW-32 oil at 75_ F (24_ C)
A 150 psi (10.3 bar) inlet air pressure
B 100 psi (6.9 bar) inlet air pressure
C 70 psi (4.8 bar) inlet air pressure
D 40 psi (2.8 bar) inlet air pressure
0
0
2
(7.57)
Fluid Outlet Pressure
A 150 psi (10.3 bar) inlet air pressure
B 100 psi (6.9 bar) inlet air pressure
C 70 psi (4.8 bar) inlet air pressure
D 40 psi (2.8 bar) inlet air pressure
4
(15.14)
Fluid Flow – gpm
(lpm)
Inlet Air Consumption
4
(15.14)
Fluid Flow – gpm
(lpm)
6
8
(22.71)
(30.28)
A
B
C
D
6
8
(22.71)
(30.28)
308608K
19