Instructions – Parts List
10:1 Fire–Ballr 425 Pump
Low–pressure, medium volume pump used to transfer grease.
1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure
180 psi (1.3 MPa, 13 bar) Maximum Air Inlet Pressure
Model No. 965124, Series B, Stubby length
Model No. 965129, Series B, 400 lb (180 Kg) drum length
For Closed Drum Mounting
Important Safety instructions.
Read all warnings and instructions in this manual.
Save these instructions.
WARNING
This pump is designed to be used only in pumping
non-corrosive and non-abrasive lubricants. Any
other use of the pump can cause unsafe operating
conditions and component rupture, which can re-
sult in fluid injection or other serious injury or fire or
explosion.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001
309407E
EN
TI2146A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fire-Ball B Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco Fire-Ball B Series

  • Page 1 TI2146A GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2: Table Of Contents

    ........Graco Standard Warranty ..... .
  • Page 3: Warnings

    D The air motor exhausts any fluids added to the input air. D Graco does not manufacture or supply the reactive chemical components that may be used in this equipment and is not responsible for injury or property loss, damage, expense, or claims (direct or consequential) that arise from the use of such chemical components.
  • Page 4 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment.
  • Page 5: Installation

    D Object being dispensed to: Follow your local code. NOTE: Always use Genuine Graco Parts and D Solvent pails used when flushing: Follow your local Accessories, available from your Graco distributor. code. Use only metal pails, which are conductive, Grounding placed on a grounded surface.
  • Page 6 Installation Mount the pump to suit the type of installation planned. WARNING Very heavy lubricants may require an inductor plate. See page 16 for the mounting hole layout and A bleed-type master air valve (B) is required to dimensions shut off and relieve air pressure that may be trapped in the air motor.
  • Page 7: Operation

    Operation Startup and Adjustment WARNING Open the bleed-type master air valve. Open the D This pump is designed to be used ONLY in dispensing valve, and slowly open the air regulator pumping non-corrosive and non-abrasive lubri- until the pump is running smoothly. After all the air is cants and greases.
  • Page 8: Troubleshooting

    Troubleshooting Before servicing this equipment always make sure to WARNING Relieve the Pressure. To reduce the risk of serious injury whenever you Note: Check all possible problems and solutions are instructed to relieve pressure, always follow the before disassembling the pump. Pressure Relief Procedure on page 7.
  • Page 9 Notes 309407...
  • Page 10: Service

    Service TI2148A Fig. 3 309407...
  • Page 11 Service Displacement Pump Repair 8. Remove washers (35*), spreaders (34*), cup WARNING packings (36*), o–ring (33*), and cup spacer (20) from the piston housing (16). To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the 9.
  • Page 12 Service 12. Slide priming plate (9) (beveled edge up) onto Check Valve Adjustment priming rod (8). Screw nut (10) onto priming rod This pump has an adjustable piston ball check. and tighten. To change the piston ball travel, loosen the locknut (4). 13.
  • Page 13 Notes 309407...
  • Page 14: Parts

    Parts Packing, vee* Spacer* TI2147A 309407...
  • Page 15 BEARING, rod guide, 10:1 shovel These parts are included in Repair Kit 237498, which may 624938 POPPET, foot valve be purchased separately. { See Graco Manual 306982 to order replacement air motor 624935 VALVE, foot 624937 ROD, priming parts. Air motor 205647 is identical to the one on 965124 624939 PLATE, priming;...
  • Page 16: Dimensions

    Dimensions 1” npt(f) Fluid Outlet 14 .6 in. (371 mm) 6.5 in. Model 965124 (165 mm) 28.5 in. Diameter (724 mm) Model 965124 13.9 in. 1/2 npt(f) (353 mm) Air Inlet Model 965129 50.8 in. 1290 mm) Model 965129 37.3 in. (947.4 mm) Priming Piston TI2146A...
  • Page 17: Technical Data

    Technical Data Fluid pressure ratio ................10:1 Air pressure operating range .
  • Page 18: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.