Page 1
Read all warnings and instructions in this manual. Save these instructions. 50:1 Ratio Fire-Ball 300 Pumps: 5000 psi (35 MPa, 350 bar) Maximum Working Pressure 50:1 Ratio Fire-Ball 425 Pumps: 4000 psi (28 MPa, 276 bar) Maximum Working Pressure 75:1 Ratio Fire-Ball 425 Pumps: 4000 psi (28 MPa, 276 bar) Maximum Working Pressure Stationary Units Part No.
D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment.
Page 3
WARNING SKIN INJECTION HAZARD Fluid from the dispense valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin is a serious injury.
NOTES: D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and drawings. D Always use Genuine Graco Parts and Accessories, available from your Graco distributor. Grounding D Air and fluid hoses: Use only electrically conductive WARNING hoses.
Page 5
Installation Note: See page 7 for the mobile mounting installation. See page 5 for hose and air accessory installation. Typical Installation For Stationary Mountings Fluid dispense line Pump ground wire Air regulator Main air supply line Air filter Pump lubricator Pump runaway valve Follow plate 06369B...
Page 6
D Install an air line lubricator (F) for automatic air motor lubrication. D Install the air regulator (C) to control pump speed Fire-Ball 300 and pressure. pump shown D On the main air supply line from the compressor, install an air line filter (E) to remove harmful dirt and contaminants from your compressed air supply.
Page 7
Installation Typical Installation For Mobile Mountings See Descriptions of air accessories on page 5. H Compressor J Hold-down rods K Truck bed L Hose reel 01612B Note: See page 5 for the stationary mounting instal- Drum With Hold-down Kit lation and page 5 for hose and air accessory installa- See Fig.Mounting 3 tion.
Operation Pressure Relief Procedure WARNING WARNING The maximum working pressure of each pump in your system may not be the same. To reduce the INJECTION HAZARD risk of over-pressurizing any part of your system, To reduce the risk of serious injury, in- be sure you know the maximum working pressure cluding fluid injection or splashing in the rating of each pump and its connected compo-...
Parts Drawings and Lists 50:1 Fire-Ball 300, 120-lb drum size Model 225014, Includes items 1 to 4 Part No. Description Qty. 239887 PUMP, 50:1 Ratio Fire-Ball 300; See 308883 for parts 222072 HOSE AND FITTING KIT; See parts on page 14 204574 COVER;...
Page 11
Parts Drawings and Lists 50:1 Fire-Ball 300, 400-lb drum size Model 225016, Includes items 1 to 4 Part No. Description Qty. 239888 PUMP, 50:1 Ratio Fire-Ball 300; See 308883 for parts 222072 HOSE AND FITTING KIT; See parts on page 14 200326 COVER;...
Page 12
Parts Drawings and Lists 50:1 Fire-Ball 300, 120-lb drum size Model 222085, Includes items 1 to 5 Part No. Description Qty. 239887 PUMP, 50:1 Ratio Fire-Ball 300; 7 or 8 See 308883 for parts 222072 HOSE AND FITTING KIT; See parts on page 14...
Page 13
Parts Drawings and Lists 50:1 Fire-Ball 300, 400-lb drum size Model 222071, Includes items 1 to 5 Part No. Description Qty. 239888 PUMP, 50:1 Ratio Fire-Ball 300; See 308883 for parts 222072 HOSE AND FITTING KIT; See parts on page 14 207366 COVER;...
Page 14
Parts Drawings and Lists Model 222076 Hose and Fitting Kit Part No. Description Qty. 205418 HOSE, air; 1/2” ID; cpld 1/2 npt(mbe); 72” long 155470 ADAPTER, 90_; 1/2 npt(m) x 1/2 npsm(f) swivel 109163 HOSE, fluid; 3/8” ID; 3/8 npt(mbe); 72” long 155494 ADAPTER, 90_;...
See the pump instruction manual for technical data including wetted parts, port sizes, maximum air consumption, maximum delivery, and so on. Sound data for the pumps on these units are as follows: 50:1 Fire-Ball 300 Pumps Tested at 100 psi (0.7 MPa, 7 bar) at 40 cycles per minute Sound Pressure Level, measured at 1 meter from unit 77.8 dB(A)
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.