INTRODUCTION CONTENTS INTRODUCTION PAGE 3 Thank you for purchasing a Calomax CB boiler. All our products are designed to give years of simple, reliable operation. To CHECK LIST ensure this, it is important that the installation and subsequent CONSTRUCTION servicing is carried out by a suitably qualified engineer in accordance with these instructions.
In hard water districts the use of a Dosaphos Scale Reducer (obtainable A suitably qualified engineer must install this unit. Plumbing and from Calomax Limited), for the alleviation of scale is recommended. (See electrical installation work is involved. Accessories - Page 13).
WEIGHT Cable entry can be made either from under the counter (through 11.5 KG 31KG CB32 CB22 the base) or above counter ( through the rear casing of the unit). CB12 If the cable enters through the rear, a hole must be pierced in * Dimension D can be increased to a maximum of 203mm by fitting of alternative tap bodies.
GENERAL OPERATION USER INSTRUCTIONS Place a suitable jug or vessel beneath the tap nozzle (On • During normal operation some external parts will the drip tray). This machine is primarily designed for filling become very hot, particularly the tap body and lid large vessels (not cups).
Scale reducer (complete with single cartridge Ref. D250 Ref. RRC (Pack of 8 refill cartridges to suit D250) For more information visit our website or call 0113 249 6681 www.calomax.co.uk Page 12 Page 13...
For assistance with any aspect of section of its circuit has become open. This would occur either because the machine, please call Calomax the machine has been switched on without first allowing it to fill with Float arm...
SPARE PARTS Spare parts are usually available ex-stock. Please (Refer to centre pages for location). quote Model & Serial Number. (See page 20) CBTT CBTS CBTSS CBWTNA CB32WP CB32BK CB32IS TWIN CAM TAP TOP SINGLE CAM TAP TAP SPRING TAP SLOTTED WATER TANK NUT WATER PIPE BODY KIT...
TROUBLE SHOOTING Wiring Schematic for Calomax CB32/22/12 Water Boilers Symptoms Possible Cause Remedy Broken tap top Replace tap top (or component) No water available Faulty float valve. (See Replace valve ORANGE ‘water fill function’ page 15) TOP THERMISTOR Excessive internal scale. (See...
12 months from the Original Date of Despatch. PLEASE CONTACT OUR SERVICE DEPARTMENT FOR ASSISTANCE Calomax Limited, Lupton Avenue, Leeds LS9 7DD Tel: 0113 249 6681 Fax: 0113 235 0358 e-mail: service@calomax.co.uk...
Need help?
Do you have a question about the CB32 and is the answer not in the manual?
Questions and answers