Page 1
INSTALLATION, OPERATION AND SERVICING INSTRUCTIONS FOR THE ECLIPSE RANGE OF WATER BOILERS Please read these instructions carefully before operating your boiler for the first time Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel. 0113 249 6681 Fax. 0113 235 0358 e-mail: service@calomax.co.uk www.calomax.co.uk...
CONTENTS PAGE INTRODUCTION CHECK LIST APPROVALS CONSTRUCTION INSTALLATION LOCATION COLD WATER INLET ACCESS INSTRUCTIONS VENT / OVERFLOW ELECTRICAL CONNECTIONS USER INSTRUCTIONS SCALE GENERAL OPERATION CLEANING TROUBLE SHOOTING ACCESSORIES SPARE PARTS 12/13 EXPLODED DIAGRAM 14/15/16/17 SERVICE INSTRUCTIONS 18/19 GENERAL FUNCTION WIRING DIAGRAM DIMENSIONS AND WEIGHTS WARRANTY PRODUCT SPECIFICATION...
INTRODUCTION Thank you for purchasing a boiler from the Calomax Eclipse range. All our products are designed to give years of simple, reliable operation. To ensure this, it is important that the installation and subsequent servicing and maintenance is carried out by a suitably qualified engineer in accordance with these instructions.
Allow clearance for ventilation and for the easy removal of the outer casing lid and front panel. Calomax ltd recommend a minimum clearance of 50mm on all sides of the boiler. A suitably qualified engineer must install this unit.
3 point fixing wall bracket .for wall mounted range Hang the boiler on the wall bracket and secure into place with 4th fixing. The electrical cable should be routed as shown. The use of 6mm Rawl-Bolts is recommended secure bracket to a wall of appropriate construction support working...
ACCESS INSTRUCTIONS Access to the internals of the machine is gained by the removal of the front panel. Prise off the outercasing lid from its mounting clips. remove the top two panel mounting screws, and the third bottom mounting screw (where fitted). Remove the cover. The 3C5C model does not have the third screw, it is fitted with two more clips at the bottom of the panel which can be prised off.
VENT & OVERFLOW The vent / overflow pipe must be extended and laid with a continuous fall, discharging to a safe and visible point. The pipe should not be directly connected to a closed waste, as taste problems may occur and should never be allowed to become blocked or restricted.15mm copper or ‘Speedfit’...
In the event of the power supply lead to the boiler becoming damaged, the appliance must be removed from service. A replacement genuine part is available from Calomax Ltd, and must be fitted by a suitably qualified engineer Commissioning Turn on the water supply and then switch on the electrical supply.
at operating temperature indicated by the Ready light being illuminated. The full light will be illuminated only when the boiler is full of boiling water. By pressing the symbol on the upper fascia label, the economy feature is selected. This feature reduces the working capacity of the appliance by approximately half.The full light will be disabled.
Replace Circuit board Element thermal cutout. The Eclipse range of boilers has an inbuilt thermal cutout device to protect the element in a boil dry situation. Should the cutout be activated, contact an approved Calomax service provider for advice. Page 10...
Spare parts are usually available ex-stock. Please quote Model & Serial Number. ETTBK (black) CBTCW CBTS CBTSS ETT (blue) TAP TOP TAP CUP WASHER TAP SPRING TAP SLOTTED ASSEMBLY STEM MHSB (BLUE) UTHS (BLACK) TN2CK DOTTK SLOW FILL NOZZLE DRAW OFF TAP DRAW OFF TAP ECLIPSE HEAT BODY...
Page 13
Spare parts are usually available ex-stock. Please quote Model & Serial Number. X8 various sizes ELPK NBPRG ESSK ECLIPSE LEVEL BODY LID GROMMET ECLIPSE SILICONE POWER SWITCH PROBES KIT SEAL KIT FIH (1m) WIH (1m) IH2M (2m) WATER INLET WATER INLET HOSE HOSE Page 13...
Page 14
Exploded parts view for Eclipse wall mounted boilers (To be read in conjunction with the spare parts list) * Complete set of 8 seals (2 sizes) Page 14...
Page 15
(inside moulding) (behind cap) If parts required are not identified, please contact Calomax Limited Page 15...
Page 16
Exploded parts view for Eclipse Counter Top Models. (To be read in conjunction with the spare parts list) * Complete set of 8 seals (2 sizes) Page 16...
Page 17
If parts required are not identified, please contact Calomax Limited (inside moulding) (behind cap) Page 17...
The unit can be used normally while the service indicator is flashing a 4x pulse. For further assistance, contact our service department on 0113 249 6681 e-mail service@calomax.co.uk. or find a local service engineer at www.calomax.co.uk Access to internal components can be gained by the removal of the outer casing lid and front panel.
Page 19
De-scale To gain access to internals of the water tank, the body lid must be removed. Remove the 4 screws, break the lid gasket seal and lift it clear of the body. Note: Whenever the body lid has been removed from the boiler a new lid gasket may be required to ensure a steam-tight joint.
Heat transfer compound is also supplied with all replacement circuit boards. Adjusting the Water Temperature Set Point The temperature potentiometer (Pot) is pre-set at Calomax and will only require adjustment in exceptional circumstances. Contact Calomax for advice.
WARRANTY GUARANTEE (UK Mainland customers only) Calomax have manufactured water boilers in the UK for over 50 years. We are proud of our products and the back-up service we provide Properly maintained and serviced, a Calomax boiler should last many years and we have no hesitation in providing a full 12 months (mainland U.K.) parts and labour warranty for all models.
Model 2W3 2kW (MAX) All other Models 3kW (MAX) Note: All measurements are approximate PLEASE CONTACT OUR SERVICE DEPARTMENT FOR ASSISTANCE Calomax Limited, Lupton Avenue, Leeds LS9 7DD Tel: 0113 249 6681 Fax: 0113 235 0358 e-mail: service@calomax.co.uk Page 24...