Page 1
Larson Davis Spartan Model 730 Noise Dosimeter Reference Manual...
Page 2
1681 West 820 North Provo, Utah, USA 84601-1341 Warranty For warranty information, visit the Larson Davis Product Warranty page. E-Labeling Notice Access important safety and conformity information on the e-label, which is displayed on the dosimeter, on the About page.
Module 1 Product Overview The Larson Davis Spartan Model 730 or 730IS dosimeter is a personal noise measuring and recording device for an individual who may be exposed to noise at work. 1.1 Dosimeter Features and Function The following easy-to-use capabilities make the Spartan 730 the best choice for your project: •...
Page 5
The Spartan 730 dosimeter is built to last. Engineered and manufactured using stringent processes and the highest quality materials. We stand behind this product and our commitment to “Total Customer Satisfaction.” FIGURE 1-2 Spartan 730 Dosimeter at Work Each dosimeter meets or exceeds all applicable international LEARN MORE standards.
Page 6
D. Cables & Accessories E. LD USB drive Accessories include: USB drive contains: • Spartan 730 Quick Start Guide • G4 LD Utility Software • LD Bluetooth dongle (DVX016) • Copy of Calibration Certificate • Electrical outlet adapter • Spartan 730 Reference Manual •...
Page 7
• 2-inch safety pins (for heavy clothing) • Spartan 730 Reference Manual 1.1.2 Serial Numbers The Spartan 730 dosimeter’s model and serial number is printed on the label on the back of the meter. The microphone serial number is engraved on the outside of the microphone.
Page 8
• Records sound events in 16-bit WAV format by using event detectors. 1.1.4 Applications The Spartan 730 or 730IS personal noise dosimeter is ideal for the following applications: • Measuring factory, airport, and mine noise • Measuring construction noise •...
Page 9
Peak Frequency Weighting: A, C & Z • Multiple language support: English, Spanish, French, Italian, German, and Portuguese 1.1.7 Available Firmware Options The following optional firmware is available for the Spartan 730 or 730IS dosimeter: Spartan 730/730IS Dosimeter Manual Dosimeter Features and Function...
Additional power supply cable with accessory plug ends (PSA029) • Additional 1” Windscreens (WS012) 1.2 Getting to Know Your Spartan 730 Noise Dosimeter This section describes the hardware and device components of the Spartan 730 Noise dosimeter. Spartan 730/730IS Dosimeter Manual...
Page 11
For additional details and specifications for each component, see Appendix A Technical Specifications. 1.2.1 Microphone and Windscreen The Spartan 730 comes with a high-quality, 1/4”, free-field, prepolarized condenser microphone (Model 375A03). The windscreen (WS012) is a 1” diameter cone made of open cell foam, which contributes to the most accurate measurement.
Page 12
Durable clips secure the dosimeter to clothing, and keep the meter in place to monitor noise exposure near the ear. The clip assembly is removable, and replacements are available from Larson Davis if needed. 1.2.4 Front LED Indicators When enabled, the multi-color LED display on front,...
Page 13
(Hours) Estimated Run Time on the Meter Screen 1.2.6 LCD Color Display The Spartan 730 has a full color, front-lighted LCD screen, which is suited for indoor or outdoor visibility. When you power the dosimeter on, you’re prompted to press select to open the Menu, or press the up or down button to dismiss the tip.
Page 14
Screen 2. the sound position is Screen 1. metrics available on this dosimeter, Press to scroll see Appendix B Glossary. horizontally Spartan 730/730IS Dosimeter Manual Getting to Know Your Spartan 730 Noise Dosimeter...
Page 15
1.2.7 Screen Details On the Spartan 730 Dosimeter Dosimeter 1–4 Screen Detail The Spartan 730 dosimeter configuration settings are displayed on the first 4 screens of the LCD. The LCD displays the current measurement data in terms of your chosen configuration for Dosimeter 1.
Page 16
Subsequent pages show OBA data in table format. The OBA Screen and associated features display when you purchase and install option 730-OB1. Table 1.1 Screens On the Spartan 730 Dosimeter Click here to return to Meter Screen Detail The Meter screen displays the following information on 3 pages: Meter–Time Page 1...
Page 17
• Total Memory, available for storage • the current internal device Temperature Table 1.1 Screens On the Spartan 730 Dosimeter Click here to return to SLM Screen Detail The SLM screen displays the following sound level meter metrics on 10 pages.
Page 18
Press down to view additional pages on the SLM Screen. SLM–Sound Exposure, Page 7 • Displays the Sound Exposure metric in dB and in Pascal-squared hours • • • E,8h Spartan 730/730IS Dosimeter Manual Getting to Know Your Spartan 730 Noise Dosimeter...
Page 19
• Slow (Smx), Fast (Fmx), Impulse (Imx), linear time (Leq), and peak time weightings (LPk) for the overall measurement. Table 1.1 Screens On the Spartan 730 Dosimeter Click here to return to Spartan 730/730IS Dosimeter Manual Getting to Know Your Spartan 730 Noise Dosimeter...
Page 20
Figure 2-4 Status Bar Detail. The Run Status includes the following states: run, stop, and pause. 1.2.9 Measurement Configurations The Spartan 730 dosimeter can calculate noise exposure using to up to 4 configurations at a time. This is accomplished using the Dosimeter 1, 2, 3, Spartan 730/730IS Dosimeter Manual...
Page 21
Manual. 1.2.10 Care and Cleaning The Spartan 730 can be cleaned using a damp cloth. To sanitize, wipe the device with 70-percent isopropyl alcohol or a disinfecting wipe. Do not use bleach. For soft surfaces—such as the windscreen and foam in the carry case—spray with a non-bleach disinfectant spray and allow it to...
2.1.2 Installing G4 from the LD USB Drive Step 1. Insert the included Larson Davis USB drive into a USB port in your PC. Step 2. Launch the Windows Explorer, and open the USB Drive (Removable Disk). Step 3. Open the G4 LD Utility Software folder, and double-click LDSetup.exe.
2.3.1 Wireless Charging The Spartan 730 is built with a convenient wireless charging capability. Charge the meter using any of the following wireless methods. If you’re using the Model 730IS (Intrinsic Safe model), you must read Appendix C " Spartan 730IS Safety Information"...
Step 1. Verify that Bluetooth is enabled on your PC. Win 7 Users: You must insert the included LD Bluetooth Dongle (DVX016) into an available USB slot to communicate with the Spartan 730. Win 10 users: For more information about enabling Windows BT, click the Start Menu and search for Bluetooth.
Page 26
Step 2. To launch G4, click the shortcut icon on your Desktop. Step 3. Locate and click on your connected Spartan dosimeter in the Meters panel. This opens a new Meter tab on the right. Spartan 730/730IS Dosimeter Manual Connecting to Your Dosimeter in G4...
Page 27
Charging the Spartan 730. Connect to the 730 Dosimeter using your mobile device’s Bluetooth radio. Because the Spartan 730 uses a Bluetooth Low Energy (BLE) connection, there is no need to pair. Step 1. On your mobile device, enable the Bluetooth feature.
In this section: • 2.6.1 Calibrating Your Spartan Dosimeter • 2.6.2 About Calibration Histories, Instrument Overload, and Calibration Stability • 2.6.3 Factory Calibration Service • 2.6.4 Larson Davis Calibrator and Accessories Spartan 730/730IS Dosimeter Manual Upgrading Dosimeter Firmware or Options...
Page 29
2.6.1 Calibrating Your Spartan Dosimeter Your Spartan 730 dosimeter begins auto-calibrating when attached to a CAL150 or CAL200 calibrator. Before you begin: • Power on the dosimeter. • Stop any measurement in progress. Step 1. Remove the windscreen by pressing down and turning counter- clockwise.
Page 30
If the meter detects a sounds louder than the overload level, the Spartan 730 displays an overload indicator on the LCD display, in the LD Atlas app, in the G4 LD Utility, and in the resulting measurement data.
Page 31
Davis USB drive. To schedule service, see the back cover of this manual. 2.6.4 Larson Davis Calibrator and Accessories The Spartan 730 dosimeter accommodates the following calibrators with a 1/4- inch adapter (ADP109). FIGURE 2-5 Larson Davis Model CAL150 or...
Page 32
The Spartan 730 dosimeter automatically keeps an internal history of all calibrations. This calibration history is permanently retained unless a format and restore to factory defaults is needed.
Page 34
80.0 80.0 80.0 User selected Shift Time User selected Frequency Weight A-Weight A-Weight A-Weight A-Weight User selected Detector Slow Slow Slow Slow Slow Peak Frequency Weight C-Weight C-Weight C-Weight C-Weight User selected Spartan 730/730IS Dosimeter Manual Defining a Measurement Configuration...
Page 35
Step 6. If you want to enable additional virtual dosimeters, do the following: Enabling or Disabling Dosimeter 2, 3, or 4 a. From the Settings menu, highlight, then Dosimeter 2. This opens select the Dosimeter 2 menu. Spartan 730/730IS Dosimeter Manual Defining a Measurement Configuration...
Page 36
Time History records taken in regular intervals allow G4 to graph the subject’s exposure level for the duration of the measurement. In the measurement configuration, Time History is defined with a 1 second or 1 minute period. With Spartan 730/730IS Dosimeter Manual Defining a Measurement Configuration...
Page 37
(or minute, respectively). About the Octave Band Analysis Option (730-OB1) The Octave Band Analysis (OBA) feature on your Spartan 730 allows you to analyze the measured noise exposure in full octaves. Industrial Hygiene professionals sometimes use octave band analysis when measuring personal noise exposure.
An exceedance occurs when the measured sound level rises above one or more of the user-defined trigger levels. For the Spartan 730, there are two threshold levels (SPL 1 and SPL 2), and three peak trigger levels (Peak1, Peak2, and Peak3). The process of setting these exceedance levels is explained in section 3.2.1.
Page 39
3.2.2 Customizing Exceedance Trigger Settings Use the processes in this section to edit how exceedance triggers are calculated. IN THIS SECTION: • Setting the Frequency Weighting • Setting the Peak Frequency Weighting • Setting the Detector Spartan 730/730IS Dosimeter Manual Defining Exceedance Triggers...
Page 40
Pk Freq Wt. This opens the SPL Pk Freq Wt screen. Step 5. Press down to highlight an available option, then press select to set your selection and return to the Detectors and Weighting menu. Spartan 730/730IS Dosimeter Manual Defining Exceedance Triggers...
Page 41
Detectors and Weighting menu. Available options include , and Impulse Fast Slow Step 6. Quick press power repeatedly to exit all menus. Spartan 730/730IS Dosimeter Manual Defining Exceedance Triggers...
3.3 Setting a Visual Alarm on the Spartan 730 The Spartan 730’s visual alarm settings enable you and the worker to be aware of milestones within the current noise exposure period. The Dosimeter 1 setting comes with 2 customizable visual alarm settings: Alarm 1, Alarm 2, which can be enabled separately, as shown in section 3.3.1 Enabling Dosimeter 1 Alarm 1.
Page 43
In this section, use on the dosimeter to DOWN highlight an option. Use to set the option. Quick SELECT press power to step up one level in a menu. Spartan 730/730IS Dosimeter Manual Setting a Visual Alarm on the Spartan 730...
Page 44
Step 3. Repeat the process shown in step 2 to set the Limit Level and return to the Alarm 1 menu. Step 4. If you want to provide real-time exposure feedback to the wearer, enable the LED alarm lights. Spartan 730/730IS Dosimeter Manual Setting a Visual Alarm on the Spartan 730...
Enabling or Disabling LED Alarm Lights When enabled, the LED alarm lights on the Spartan 730 provide exposure feedback to the wearer based on the Source metric, and the Action and Limit levels you set. The LED is yellow when the exposure level is between the action and limit levels, and red when the exposure is equal to or above the limit level.
Page 46
3.4.2 Setting a Daily Measurement Timer The Spartan 730 enables you to set one or more time periods per day (daily timers) during which the dosimeter will automatically power on, take a Spartan 730/730IS Dosimeter Manual...
Page 47
Stop Date from the list. This opens the Stop Date screen. Step 8. Set a value for the timer Stop Date in yyyy-mm-dd format. This return you to the Timers menu. Repeat the process shown in step 7. Spartan 730/730IS Dosimeter Manual Setting a Measurement Timer...
Page 48
Stop any measurement in progress. In this section, use on the dosimeter to DOWN highlight an option. Use to set the option. Quick SELECT press power to step up one level in a menu. Spartan 730/730IS Dosimeter Manual Setting a Measurement Timer...
For more information, open G4 and go to Help Manuals G4 LD Utility Manual 10.1 Creating a Measurement Configuration File in G4. Recommended Next Step: Module 4 Making a Measurement • Spartan 730/730IS Dosimeter Manual Setting the Measurement Configuration in G4...
SELECT Step 1. Press and hold the select button to enter the Menu. Step 2. Highlight, then Run. The measurement begins. select Recommended Next Step: • 4.3 Deploying the Dosimeter Spartan 730/730IS Dosimeter Manual Making a Measurement...
Page 51
5.2 Merging Data Files in G4. Before you begin: • Begin a measurement as shown in section 4.1 Making a Measurement, or from the LD Atlas app or G4. Spartan 730/730IS Dosimeter Manual Making a Measurement...
Page 52
Stop. The measurement ends. 4.1.3 Making a Measurement in Locked Run Mode The Spartan 730 dosimeter enables you to lock the dosimeter display. This prevents the wearer from accidentally or incidentally tampering with measurement data. When the dosimeter is locked, use the LD Atlas app or G4 to unlock it.
Spartan dosimeters in the same area. If the noise exposure you’re measuring occurs at a specific time, you can use the Spartan 730’s timers—a timed stop or a daily timer—to obtain the best noise exposure sample. Spartan 730/730IS Dosimeter Manual...
Page 54
A timed stop takes a measurement for the duration you set. You can set a timed stop on the Spartan 730, in the LD Atlas app, or in the G4 LD Utility. To set a timed stop on the dosimeter, see section 3.4.1 "Setting a Timed Stop Measurement Timer"...
Page 55
Motion, or lack of motion, during the measurement is displayed along the bottom of the chart. FIGURE 4-2 Time History Chart in the G4 LD Utility No Motion Motion Spartan 730/730IS Dosimeter Manual Best Practices for Measuring Noise Exposure...
When your measurement is complete, you’re ready to download and interact with the data files using the LD Atlas app or G4. Recommended Next Step: • Module 5 Working With Dosimeter Data Files. Spartan 730/730IS Dosimeter Manual Deploying the Dosimeter...
• 5.1.4 Downloading Data Files Manually The Spartan 730 dosimeter’s helpful auto-download feature is enabled by default when you use G4. After the measurement, bring the dosimeter within Bluetooth range (or connect using the included USB cable) and your files automatically begin downloading.
Page 58
This section shows how to add a dosimeter download exception to the Individual Cases list. Meters on the list are excluded from the auto-download feature. Step 1. In G4, go to Tools Options. This opens the G4 Options window. Spartan 730/730IS Dosimeter Manual Downloading Data Files in G4...
Page 59
If you want the dosimeter to again be excluded from the auto-download, repeat this process from step 1. (Step 3 deselects the Download checkbox.) Recommended Next Step: • 5.3 "Viewing Measurement Results in G4" on page 59 Spartan 730/730IS Dosimeter Manual Downloading Data Files in G4...
Page 60
5.1.4 Downloading Data Files Manually The Spartan 730 comes with a helpful auto-download feature enabled. When enabled, measurement data files begin downloading when the meter comes within Bluetooth range of your PC. 5.1.1 Enabling or Disabling To enable or disable auto-download, see LEARN MORE Auto-Download in G4.
5.3 Viewing Measurement Results in G4 For complete information on viewing measurement results, open G4 and go to Help Manuals G4 LD Utility 10.6 Viewing Measurement Results in G4. Spartan 730/730IS Dosimeter Manual Merging Data Files in G4...
Help Manuals G4 LD Utility 4.8 Accessing Audio Files in G4. 5.4 Creating a Report For more information about this feature, in G4 go to Help Manuals G4 LD Utility Manual 10.6.4 Creating a Report. Spartan 730/730IS Dosimeter Manual Creating a Report...
You can use G4 or LD Atlas to listed to sound recordings. IN THIS SECTION: • Part 1: Setting Options for Event Recording • Part 2: Disabling Event Sound Recording Spartan 730/730IS Dosimeter Manual Setting Event Sound Recording Options...
Minimum Interval is the number of seconds between event recordings. The default setting is 30 seconds. Set a longer Min Interval to minimize the number of recorded events and conserve dosimeter memory. Spartan 730/730IS Dosimeter Manual Setting Event Sound Recording Options...
6.2 About the Dosimeter Noise Level The dosimeter noise level setting is a factory configuration that rarely requires adjustment. Among other things, it is used to compute the meter’s under-range level. Spartan 730/730IS Dosimeter Manual About the Dosimeter Noise Level...
6.3 Customizing the Dosimeter Name The default name of each dosimeter is “Spartan 730” + the meter’s serial number. This section reviews how to change this to a custom name. Please note that the name you set on the dosimeter will only display in the LCD and in the resulting data file.
24-hour (hh) format. b. Press select to set the hour and highlight the minute (mm). c. Repeat steps a–b to set the minute and advance to the second (ss). Spartan 730/730IS Dosimeter Manual Setting Date and Time Manually On the Meter...
Step 4. Press down to highlight an available option, then press select set your selection and return to the Preferences menu. Available options include Period Comma Step 5. Quick press power to exit all menus. Spartan 730/730IS Dosimeter Manual Setting Localization Preferences...
6.6 Disabling or Enabling Auto Shut-Off With the Auto Shut-off setting enabled, when the Spartan 730 is not taking a measurement and is inactive for 30 minutes, it powers off. The meter remains active with a Bluetooth connection to the LD Atlas app or G4, or any button press.
Step 5. Then, press the power button for 1 second to attempt to power the meter. If the meter powers on, move to step 6. If the meter does not power on, contact Larson Davis to begin the RMA/repair process. Contact Larson Davis.
-40.0 dB ±3.0dB relative to 1V/Pa (nominal 10 mV/Pa) 20 Hz to 5 kHz (±2 dB) Typical Sensitivity >5 kHz to 8 kHz (±3 dB) >8 kHz to 12.5 kHz (+3 / -∞ dB) CONTINUED ON NEXT PAGE Spartan 730/730IS Dosimeter Manual...
Page 72
FIGURE A-1: A-Weighted RI Frequency Response of Supplied Microphone FIGURE A-2: C-Weighted RI Frequency Response of Supplied Microphone Spartan 730/730IS Dosimeter Manual...
Page 73
BLE 4.1 Type 30 mW viewing/downloading data Power Use 22k B/s (typical) Throughput Android and iOS devices using LD Atlas app Supported Hosts PC with Microsoft Windows 7 or newer using G4 LD Utility software Battery Spartan 730/730IS Dosimeter Manual...
Page 74
Powered by computer or (PSA029) power adapter Using USB Client Connector 5.0 ±0.5 V, 5.5 V absolute maximum (Um = 5.5V) Qi® WPC-compatible charge pad (PSA042) Using Wireless Charger 5.0 ±0.5 V, 5.5 V absolute maximum input voltage (Um = 5.5VDC) Spartan 730/730IS Dosimeter Manual...
Page 75
All specs include clips and windscreen 206 x 54 x 44 mm 8.11 x 2.13 x 1.73 in Dimensions 112 g 4.2 oz Weight IP65 Ingress Protection Rating Physical Characteristics-Model 730IS metric All specs include clips and windscreen Spartan 730/730IS Dosimeter Manual...
Page 76
Peak Frequency Weightings ρ indicated by ≤55 µs Peak Rise Time 32k sps Sample Rate A.1.3 SLM Specifications SLM Live View Metrics Units Linear Aeq(1s) Ceq(1s) Zeq(1s) Slow Fast Impulse Peak Apeak, 1s Cpeak, 1s Zpeak, 1s Spartan 730/730IS Dosimeter Manual...
Page 77
Ceq - equivalent levels Exceedance Metrics Exceedance trigger levels (SPL1 and SPL2) selectable in dB from 40.0 to 140.0, and Peak Exceedance levels (Peak1–3) selectable in dB from 80.0 to 143.0, counts each time the level rises Spartan 730/730IS Dosimeter Manual...
Page 78
Maximum Exposure (limit 140 dB for 200 hours) 7.90E+06 Minimum Exposure (limit 50 dB for 1 second) 7.90E-03 Measurement Control Multiple control and timer modes provide for the following manual and automated measurements: • Manual: Manually control measurements using Run, Stop, and Pause. Spartan 730/730IS Dosimeter Manual...
Page 79
Noise Dose Percentage, Criterion Level and Time set 100% exposure limit ProjDose Projected Noise Dose Percentage, Criterion Level set 100% exposure limit TWA(8) Time Weighted Average for Criterion Time of 8 hours with Threshold P. TWA(8) Projected Time Weighted Average with Threshold Spartan 730/730IS Dosimeter Manual...
Page 80
100 (% or dB) Limit Level A.1.5 OBA Specifications The following specifications apply to the Spartan 730/730IS dosimeter option 730-OB1, which is available for purchase from Larson Davis. IEC 61260-1:2014/Part 1, 1/1 Octave Bands, Class 1, Group X, all filters...
Page 81
Exceedance Detector setting (Slow, Fast, Impulse). Linear Units Overall Metrics Overall Equivalent Level Spectrum eq(f) Overall Maximum Level Spectrum Ƭmax(f) Overall Minimum Level Spectrum Ƭmin(f) A.1.6 Time History Specifications 1 sec, 1 min Period Spartan 730/730IS Dosimeter Manual A-11...
Page 82
Time Weighted Average (Q5) (t) TWA5 Overload, Motion, Bump, Run, Stop, Pause Other Indicators A.1.7 Event Sound Recording Specifications The following specifications apply to the Spartan 730 dosimeter option 730-ESR. 16-bit WAV File Format 8000 sps Sample Rate 2 second pretrigger...
Page 83
Other Standards: Test Results and Certificates RoHS/IC/FCC compliant with ISO 17025 FIGURE A-4 BLE Module Markings Contains transmitter module with certificate number: 210-106799 R-CRM-Rgd-BMD-300 Contains ANATEL approved module #03154-18-11156 Este equipo contiene el módulo con IFT #: NYCE/CT/0146/17/TS Spartan 730/730IS Dosimeter Manual A-13...
Page 84
Operating the Spartan 730 in proximity to a source of electromagnetic radiation equal to 10 V/m may cause up to ± 1.5 dB variation on the sound exposure level reading. The Spartan 730 meets all of the standards of section 15 in IEC 61252 (2017) at a sound level of 85 dB.
Page 85
The Spartan 730 dosimeter complies with ANSI S1.25-2007 as specified below. Class 2 with variable A or C frequency weighting, variable for F or S time constant, Class Designation variable Criterion Level, Threshold, and Exchange Rate. Overload is indicated when the upper limit has been exceeded and held for 4 Upper Limit Indicator seconds.
Page 86
A.2.5 IEC 61252 Compliance The following compliance is provided for the Larson Davis Spartan 730 dosimeter according to IEC 61252 Ed. 1.2. See Table A-1 on page A-17. Spartan 730/730IS Dosimeter Manual A-16...
Page 87
BNC to 1/4-inch Mic 12 pF) electromagnetic field emitter or receiver. The electrical impedance of the source 14.l The mode of operation of the Spartan 730 that Ω connected to the ADP106 shall be 600 or less. produces the greatest radio frequency emission 14.bb...
Appendix B Glossary This glossary contains technical definitions of key acoustical and vibration terms commonly used with Larson Davis instruments. If you need additional information, please refer to the American National Standards Insti- tute document S1.1-1994 (R2004) for additional definitions. Specific use of the terms defined are in the main body of this manual.
Page 89
Calibration Adjustment of the system so that the measured sound level agrees with a reference sound source. Calibration Check A check for variations between the measured level and a reference level—no adjustment is made to the system. Criterion Duration The time required for a continually applied sound of the selected criterion level to produce a dose of 100%. Criterion Duration is 8 hours by the standard for dosimeters.
Page 90
Decibel (dB) A unit of measure commonly used to describe the ratio of one power level or field level value to another on a logarithmic scale. The decibel is a simplified way of representing a large span of signal levels, and sometimes very large numbers, as opposed to using the Pascal.
Page 91
Equivalent Time-Weighted Average TWA(x) The level of a constant sound, expressed in dB, which if measured for a time period equal to the Criterion Duration, will produce the currently measured noise dose. = average sound level in dB, only recording values higher If exchange rate = 3, q = 10 than the user specified threshold level If exchange rate = 4, q = 4 / log...
Page 92
Exchange Rate, Exchange Rate Exposure Factor, Factor, q 6.02 Frequency (Hz, rad/sec) The rate at which an oscillating signal completes a complete cycle by returning to the original value. It can be expressed in cycles per second and the value has the unit symbol Hz (Hertz) added, with the letter f used as a universal descriptor for frequency.
Page 93
of the quantity and not the quantity itself. The word decibel is often added after the number to express the same thing. When frequency weighting is used the annotation is often expressed as dB(A) or dB(B). See also "Decibel (dB)." The maximum value, expressed in dB, of the Frequency and Exponential-Time Weighted Sound Level ( ) in a ωτ...
Page 94
Peak Frequency Weighting The frequency weighting of the peak detector. Possible selections are A, C, Z. Peak weighting is independent of the RMS frequency weighting. For additional information, see the entry for “Frequency Weighting”. Projected Daily Personal Noise Exposure (P. L or P.
Page 95
Projected Sound Exposure (E or E Projected Sound Exposure shows what the actual sound exposure will be for a specific time period if the current Equivalent-Continuous Sound Level (L ) remains at its current level. The dosimeters calculate an 8-hour and a 40- hour projected sound exposure.
Page 96
Air (wind) blowing across the microphone generates pressure fluctuation and vibration on the microphone diaphragm. Thus, your noise exposure reading would include wind noise, an undesirable component. To achieve the best result with the Spartan 730 dosimeter, we recommended using the provided WS012 windscreen. 730/730-IS Dosimeter Manual...
Class I, Division 1, Groups A, B, C & D, T165 ºC UL 61010-1: Edition 3 + R:29Apr2016 Cert to CAN/CSA Std C22.2 CAN/CSA C22.2 No. 61010-1-2012 + U1 Ex ia IIC T165 ºC Ga -10 ºC ≤ TAMB ≤ +50 ºC Spartan 730/730IS Dosimeter Manual...
Page 98
Do not attempt to open or repair the device. Improper repair or opening can lead to the destruction of the device, fire, or explosion. Only authorized personnel are prepared to repair the device. See the back cover of this manual to contact Larson Davis for service or repairs. •...
Page 99
We highly recommended that you return a device that shows signs of faults or damage, or is suspected of faults or damage, to Larson Davis for inspection. Contact information is located on the back cover of this manual.
Page 100
Do not replace the battery yourself or attempt to install a lithium battery. Without exception, contact Larson Davis for authorized battery replacement. • Only use accessories approved by Larson Davis with this device. Applicable Standards IEC 60079-0: Edition 7; EN 60079-0:2018 IEC 60079-11: Edition 6;...
Need help?
Do you have a question about the Spartan 730 and is the answer not in the manual?
Questions and answers