Installation

1. In the first time, add the device into the Z-Wave
make sure the primary controller is in the inclusion mode. And then
power on the device, just take out the insulation Mylar in the back side
of the device. The device will auto start the NWI (Network Wide
Inclusion) mode. And it should be included in 5 seconds. You will see
the LED light ON one second.
2. Let Controller associate with Group 1 of the device, any light switch
that intend to be turned on when the device trig please associate to
Group 2 of the device.
3. In the accessory pack. There are two type of double coated tape,
one is thicker (hereinafter referred to as A tape) and another is thinner
(hereinafter referred to as B tape), you can use A tape for the test at
the beginning. The right way for A tape installation is stick it to the
position below tamper key. The thicker tape won't let the tamper key
close, so the sensor will enter the test mode, You may test if installed
position is good or not by this way.
After finish the test and decide to fix, then you can remove tape A, and
mounting the sensor by using tape B. This will close the tamper key
TM
network. First,
and let the sensor enter normal mode.

Z-Wave Configuration Settings

Notice: The data size of the configuration settings is 1.
NO.
2
5
Valid
Name
Default
Values
Basic Set Level 255
1~100,
0xFF
Description
Setting the BASIC command value to
turn on the light. The 0xFF(-1) means