Operation Verification Test

The Operation Verify Test procedure is used to verify normal operation of the machine.
Perform these operation verification tests at the end of a maintenance procedure or any time it
is necessary to ensure that the treadmill is operating properly.
Note: This procedure cannot be performed when there is an active fatal error code. Repair
and reset any fatal error code condition before performing this procedure.

Procedure

1. Plug in the power cord and set the treadmill ON/OFF breaker switch to ON.
2. Verify successful power up.
A successful power up will open to the default Welcome screen.
Note:
If the console powers up showing an error code, cycle power to reset the
Error Code. If the error code cannot be cleared, you will need to resolve the
error before continuing with this operation verification tests
Note: If this is the initial power up, the console will open to the console setup screen. Follow
prompts to set up and configure the console (refer to the Owner's manual).
3. Verify that there are no active Error Codes.
a. First fix any error codes that are shown at power up.
b. Then open the Error Log (refer to the Error Log section) and make sure that
there are no active error codes. Resolve any active error codes and clear the
Error Log before continuing.
4. Access the Diagnostics service menu (51765761) and perform the following
Hardware Validation system tests the R20 or R40 console (refer to the Standard
Service and Diagnostics Software "Performing System Tests" section):
5. R40 Console: Perform the following R40 diagnostic tests:
Use the UP/DOWN arrow softkeys to scroll and browse tests.
Press the Test softkey to start a test and then follow prompts to run the test.
Press the Home softkey to exit the Diagnostics menu.
Test
Display GUI/Metric
Test
Key Test
Heart Rate Test
Belt Speed Test
Incline Test
© 2014 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Description
Backlight brightness is varied and cycles thru
numbers.
Tests the function keys.
Test the heart rate and SmartRate functions, the
heart rate is acquired and shown.
Select the SPEED control to vary the running belt
speed from 0.5 mph to 12.0 mph in 0.1 increments.
Select the INCLINE control to raise and lower the
deck. The incline A/D value is shown and verified at
the following incline settings:
37 ±5 @ 0% incline
Page 9 of 56