7 Commissioning the Router Kit LAN / LTE

7.3 Configuring SCALANCE M876-4

8. Set the following properties in the "Internet Protocol Version 4 (TCP/IPv4) Properties"
dialog:
– Set the check mark for "Use the following IP address".
– Set the check mark for "Use the following DNS server addresses".
Figure 7-4
7.3 Configuring SCALANCE M876-4

7.3.1 Logging in to the Web-based Management Tool

Procedure
9. Commission the device.
10. To log in to the Web-based Management Tool, enter the IP address of the LTE module
(192.168.1.1) in the browser.
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch
IP address: 192.168.1.10
(Fixed IP address of the adapter. You can also select any other IP address that is in
the address range of the LTE module.)
Default gateway: 192.168.1.1
(In general: The IP address of the LTE module is entered as default gateway)
Preferred DNS server: 192.168.1.1
(In general: The IP address of the LTE module is entered as preferred DNS server)
Entering Internet protocol properties