5 Commissioning the Router Kit WLAN / LTE
5.2 Setting up interfaces
41. Set the following properties in the "Internet Protocol Version 4 (TCP/IPv4) Properties"
dialog:
– Set the check mark for "Use the following IP address".
– Set the check mark for "Use the following DNS server addresses".
Figure 5-4
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch
IP address: 192.168.1.10
(Fixed IP address of the adapter. You can also select any other IP address that is in
the address range of the LTE module.)
Default gateway: 192.168.1.1
(In general: The IP address of the LTE module is entered as default gateway)
Preferred DNS server: 192.168.1.1
(In general: The IP address of the LTE module is entered as preferred DNS server)
Entering Internet protocol properties