Location Requirements - Kenmore W10562379A Installation Instructions Manual

Electronic gas and electric dryer
Table of Contents

Advertisement

Available languages

Available languages

LOCATION REQUIREMENTS

You will need:
A location allowing for proper exhaust installation.
See "Venting Requirements."
A separate 15 or 20-amp circuit needed for gas dryers and
30-amp circuit needed for electric dryers.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), clothes may not
tumble properly and automatic sensor cycles may not operate
correctly.
For garage installation, place dryer at least 18" (460 mm)
above floor.
Steam models only: Cold water faucets located within 4 ft.
(1.2 m) of the water fill valves, and water pressure of 20-100
psi (137.9-689.6 kPa). You may use the water supply for your
washer using the "Y" connector provided.
Do not operate your dryer at temperatures below 45° F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic sensor cycle. this can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check codes requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
6
INSTALLATION CLEARANCES
The location must be large enough to allow the dryer door
to open fully.
DRYER DIMENSIONS
Models with riser
Side view
Models without riser
Side view
Bottom view:
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See
"Venting Requirements."
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
Companion appliance spacing should also be considered.
Back view
Back view