10.TROUBLE SHOOTING

PROBLEM
The boiler does not reach
to set temprature while
operating
The boiler does not reach
to set temprature while
operating and fuel
consumption is too high
There is gas clogging
when the boiler is on
sleep mode
When the boiler reached
set value, the temprature
does not become
stable,increases
The fan does not stop
when it reaches to
thermostat value
There is tar and soot
inside the boiler and
chimney
The boiler reached to set
temprature but the house
is still cold
The grill handle does not
move
The boiler burns too hard
and stops for too long
REASON
-
Low quality coal
-
Soot is accumulated
on flame pipes
-
Low quality coal
-
There is an over
draught in the
chimney
-
Soot is accumulated
around flame pipes
-
Thermostat is
broken
-
There is an over
draught in the
chimney
-
Thermostat is
broken
-
Low quality fuel
-
The burning is done
with low
temprature. Burning
air is not sufficient
-
Chimney draught is
not sufficient
-
Problem in
installation system
-
Coal or a hard
particle is clogged in
between the grill
-
Low quality fuel
-
There is soot
between flame
bender pipes
-
Burning air is
insufficient
SOLUTION
-
Change the fuel
-
Remove the soot
from the boiler
-
Change the fuel
-
Decrease draught by
reinforcement
Remove the soot from the
boiler
-
Thermostat must be
replaced
-
Decrease draught by
reinforcement
-
Thermostat must be
replaced
-
Change the fuel
-
Increase temprature
-
Check airing of the
boiler surroundings
-
Increase chimney
draught
-
Check pipe isolation,
building isolation
and radiator
quantity
-
Check the grill
-
Change the fuel
-
Clean the boiler
-
Supply fresh air to
chimney draught fan
and surroundings

Advertisement