5. TECHICAL SPECIFICATION
Boiler Type
18 MKK 25 MKK 40
Capacity(kcal/h)
18.00
0
Heating
21
Power(kW)
Weight(kg)
232
Working
3
Pressure(bar)
Test Pressure(bar) 4,5
H(mm)
1130
h(mm)
155
L(mm)
570
W(mm)
670
w1
180
w2
250
ø D
130
Circulation
1"
Flow /Return
Safety Flow
1"
Safety Return
1"
Filling-
Pouring(mm)
1/2"
Boiler
Adjustment
35/90 35/90 35/90
Range ( °C)
Boiler Water
Volume (lt)
32
Open expansion
(lt)
45
Voltage(V/Hz)
230/50 230/50 230/50 230/50 230/50
Power (W)
160
Electric Isolation
14A
Level
TECHNICAL SPECIFICATION
60
MKK
MKK
25.00
40.000 60.000 80.000
0
29
4
6
6
9
256
290
345
3
3
3
4,5
4,5
4,5
1280
1375
1510
155
155
155
570
570
660
670
825
825
180
250
250
250
250
250
130
160
160
1"
1 1/4"
1 1/2"
1"
1"
1 1/4"
1"
1"
1 1/4"
1/2"
1/2"
1/2"
35/90
8
46
1
117
60
100
150
95
160
188
14A
14A
14A
80 MKK 100 MKK 150 MKK 200 MKK 300 MKK
100.000 150.000
93
116
174
400
500
800
3
3
3
4,5
4,5
4,5
1620
1660
1780
155
155
155
660
800
800
825
950
1215
250
250
250
250
250
310
160
180
250
1 1/2"
2"
DN65
1 1/4"
1 1/4"
1/2"
1 1/4"
1 1/4"
1 1/4"
1/2"
1/2"
1/2"
35/90
35/90
35/90
174
187
380
200
250
375
230/50
230/50
95
95
225
14A
14A
14A
400 MKK
200.000 300.000
232
348
1050
1750
3
3
4,5
4,5
1795
1625
155
155
800
1540
1620
1750
290
220
310
310
250
350
DN65
DN100
1 1/2"
1 1/2"
1 1/4"
1 1/4"
1/2"
3/4"
35/90
35/90
586
1200
500
750
230/50
230/50
225
605
14A
14A
400.000
465
2208
3
4,5
1625
155
1540
2130
220
310
350
DN100
2"
1 1/2"
3/4"
35/90
1600
1000
230/50
605
14A