Routine Inspection And Maintenance; Requirement Of Inspection And Maintenance; Main Points For Inspection And Maintenance - DAYLIFF SUNVERTER 3 Installation & Operating Manual

Ac solar pump controller
Table of Contents

Advertisement

6. SERVICE AND MAINTENANCE

6.1 Routine Inspection and Maintenance

Sunverter is affected by ambient temperature, humidity, dust, vibration and internal
device aging. To ensure long term operation a yearly inspection is recommended.

6.2 Requirement of Inspection and Maintenance

The inspection must be performed by a qualified technician.
_
Ensure to cut off power supply of the inverter before carrying out any repair.
_
Avoid leaving the metal components in the inverter as they may cause damage to
_
the equipment.
Electric insulation test is already carried out on the inverter before leaving the
_
factory. If it is however necessary to conduct insulation test on the inverter, all the
input and output terminals must be reliably grounded. It is not advisable to
conduct insulation test on single terminal.
It is not advisable to use the megohmmeter to test the control circuit.
_
When conducting insulation test on the motor, dismantle the connection between
_
motor and inverter.

6.3 Main Points for Inspection and Maintenance

Inspect and maintain as per the table below.
Inspect Frequency Inspection
Routine
Regular
Inspection
on Item
Parameter
1. Temperature
Operating
2. Humidity
Environment
3. Dust, gas
1.Installation
Cooling
Environment
System
2. Radiator
1. Vibration,
Inverter
Temperature rise
Body
2. Noise
3. Wire, terminal
1. Vibration,
Motor
Temperature rise
2. Noise
Input & Output
1. Input voltage
Parameter
2. Output current
Allowable Standard
1. Temperature<50 C
2. Humidity<90% No dew condensation.
3. No peculiar smell, flammable, explosive
gas
1. Installation environment with good
ventilation
2. Radiator air duct should not been blocked
1. Stable vibration, normal temperature of the
housing
2. No abnormal noise and peculiar smell
3. Fastening screws not loose
1. Steady running and normal temperature
2. No abnormal and non uniform noise
1. Input voltage in the specialized range
2. Output current should be below rated value
6 20 6