Others; Water Level Switch Installation For Well/Tank; Water Level Switch Wiring Diagram - DAYLIFF SUNVERTER 3 Installation & Operating Manual

Ac solar pump controller
Table of Contents

Advertisement

To wire for well application, pass the water level switch cable through the
waterproof PG terminal and connect to the I3 and COM terminals(remove the
short-circuit strip between the two first), for tank application, connect to the I1 and
COM terminals as shown in Fig. 12.
Fig 11: Water Level Switch
Installation for Well/Tank

3.7 Others

A DC circuit breaker should be installed as protection switch for solar DC input.
Ÿ
The inverter has one pair of DC input terminals. If the solar modules are multi-
Ÿ
paralleled, an additional solar combiner box is necessary.
The inverter must be grounded reliably and the grounding cable properly sized and
Ÿ
as short a possible. If possible, the inverter should be grounded separately.
In areas with high incidence of lightning, it is recommended to install an external
Ÿ
surge protector at the power input of the inverter.
If the inverter is far from the motor (>200m), it is recommended to install on output
Ÿ
reactor or filter.
It is recommended to install input and output reactors, dedicated filters and
Ÿ
magnetic rings at the input and output of the inverter which can effectively reduce
the noise and avoid interference with other components.
Consult nearest Davis & Shirtliff dealer for the extra accessories such as PV
Ÿ
disconnect switch/DC breaker, combiner, surge suppressor and reactors.
Model
SV3/1.5M
SV3/2.2M
SV3/3.7M
SV3/3.7T
SV3/5.5T
SV3/7.5T
SV3/11T
SV3/15T
SV3/18T
SV3/22T
AC Breaker (A)
25
40
50
25
25
40
50
63
63
100
Fig 12: Water Level Switch
Wiring Diagram
DC Breaker
16A/750VDC
25A/750VDC
25A/750VDC
16A/1000VDC
25A/1000VDC
25A/1000VDC
40A/1000VDC
63A/1000VDC
4
63A/1000VDC
80A/1000VDC