3.2.67 mac set_tx_interval <Interval>
<Interval>: A decimal string representing TX (LoRaWAN Uplink) interval (ms), it can be between 5000
to 86400000.
Response: Ok, if <Interval> string is valid.
Invalid, if <Interval> string is not valid.
Default value is 5000.
Purpose: User can assign the interval between two TXs (LoRaWAN Uplinks) when it's under tx cycle
mode and the duty cycle control is turned off.
Example:
mac set_tx_mode cycle
>> Ok
S76G/S78G Commands Set Reference