2. Configuration
2.1 Hardware Configuration
S76G/S78G EKB can be controlled by connecting TX (PA9) and RX (PA10) UART1 interface to
other MCU, as shown in Figure 2.1, or by connecting micro USB port directly to PC/NB as shown
in Figure 2.2, The control commands can be sent from PC or other MCU to S76G/S78G.
2.2 Software Configuration
The default baud rate of S76G/S78G UART1 is set at 115200. And the rest of UART1 setting,
please follow these below settings:
Baud rate: 115200
Data bits: 8
Stop bits: 1
Parity: none
Flow Control: none
Forward: none
Figure 2.1