Download Print this page

AcSiP S76G Command Reference Manual page 28

Commands set reference

Advertisement

Purpose: Set retry number of transmission.
Example:
mac set_txretry 8
>> Ok
3.2.16 mac set_rxdelay1 <Delay>
<Delay>: a decimal string representing delay interval in milliseconds used for receive window 1, it
can be from 950 to 64000. Delay interval of receive window 2 will be set to <Delay>+1.
Response: Ok, if <Delay> string is valid
Invalid, if <Delay> string is not valid.
Purpose: Set delay interval of receive window 1.
Example:
mac set_rxdelay1 1000
>> Ok
3.2.17 mac set_rx2 <DataRate> <Frequency>
<DataRate>: a decimal string representing data rate of second receive window, it can be 0 to 7
(EU868 or AS923), 0 to 5 (CN470), 0 to 15 (US915).
<Frequency>: a decimal string representing operation frequency of specified channel in Hz, it can be
from 902000000 to 932000000 (US915); from 470000000 to 510000000 (CN470); from 433000000
to 932000000 (Other regions).
Response: Ok, if <DataRate> and <Frequency> strings are valid
Invalid, if <DataRate> and <Frequency> strings are not valid.
Purpose: Set data rate and operation frequency used for second receive window.
Example:
mac set_rx2 0 868000000
>> Ok
3.2.18 mac set_sync <SyncWord>
<SyncWord>: a hexadecimal string representing sync word, it can be from 0 to FF.
Response: Ok, if <SyncWord> string is valid
Invalid, if <SyncWord> string is not valid.
Purpose: Set the sync word used for communication.
Example:
> mac set_sync 34
>> Ok
S76G/S78G Commands Set Reference
Product Name
Version
v1.6.5
Doc No
Date
July 2, 2018
Page
27 of 73

Advertisement

loading

This manual is also suitable for:

S78g