3.1.4 sip get_hw_model
Response: A string representing hardware model.
Purpose: Get hardware model name.
Example:
sip get_hw_model
>> S76G
3.1.5 sip set_echo <Status>
<Status>: A string representing echo status, it can be on or off.
Response: Ok, if <Status> string is valid.
Invalid, if <Status> string is not valid.
Purpose: Enable or disable UART echo mode.
Example:
sip set_echo on
>> Ok
3.1.6 sip set_log <Log_Level>
<Log_Level> debug: show all logs, info: only shows commands set when input/output.
Response: Ok, if <Status> string is valid.
Invalid, if <Status> string is not valid
Purpose: Select which level when logs show
Example:
sip set_log info
>> Ok
3.1.7 sip sleep <Time> <Interruptible>
<Time> A decimal string representing S76G/S78G sleep time in seconds, it can be assigned from 10
to 604800, and the input value must be the multiple of 10.
<Interruptible> During the period of sleep mode, it can be decided to be interrupted by UART or not.
uart_on means it can be interrupted (waked up) by UART; uart_off means it can't be interrupted by
UART.
Response: Ok, if <Status> string is valid.
Invalid, if <Status> string is not valid
Purpose: Let S76/78S enter sleep mode by an assigned sleep time
Example:
(It can be triggered by any UART input.)
sip sleep 100 uart_on