SSP 200 • Setup Guide (Continued)
Mounting and Cabling
Step 1 — Mount the device
a.
Turn off or disconnect all equipment power sources.
b.
Mount the SSP 200 using optional rack and under-furniture mounting kits (available at www.extron.com), or place on a table
using the provided rubber feet. The SSP 200 is housed in a 1U-high, 8.5 inch deep, half-rack wide enclosure.
Step 2 — Connect inputs
Make the following input connections as needed (see figure 1,
Connect digital sources to Inputs 1 through 4 depending on connector type.
Connect balanced or unbalanced analog audio sources to Input 5 through the 6-pole input connector.
Step 3 — Connect outputs
Make the following output connections as needed:
Connect balanced or unbalanced analog audio output devices to the captive screw output connector (
Wiring
on the next page for more information. A representative application diagram is shown below.
Extron
Ch. 1 & 2
SF 10C SUB
Bridged
Subwoofer
100-240V
1.5A, 50-60 Hz
XPA 4002
REMOTE
LIMITER/
PROTECT
12
1
2
G
14
GREEN - ACTIVE
18
AMBER - STANDBY
26
SIGNAL
Extron
XPA 4002
Power Ampli er
Audio
12
10
12
10
8
8
LIMITER/
14
6
14
6
PROTECT
18
4
4
1
1
26
2
2
0
0
100-240V
0.6A, 50-60Hz
1
2
1 2
XPA U 1002
SIGNAL
ATTENUATION
Extron
XPA U 1002
Power Ampli er
Figure 2.
Typical Application Diagram for a 5.1.4 Speaker Setup
Step 4 — Connect control devices
To control the SSP 200 through Ethernet, connect a LAN or WAN to the LAN connector (
For serial RS-232 control, connect a host device to the 3-pole captive screw connector (
For control through USB, connect a host device to the front panel USB mini-B port (see
Step 6 — Connect power
Connect a 100 to 240 VAC, 50-60 Hz power source to the AC power connector (figure 1,
2
Extron
XPA U 1004
Power Ampli er
10
12
8
12
LIMITER/
14
6
14
PROTECT
18
4
1
26
2
0
100-240V
1.0A, 50-60Hz
1
1 2 3 4
XPA U 1004
SIGNAL
ATTENUATION
INPUTS
BRIDGE MODE
8 / 4
OUTPUTS
BRIDGE
BRIDGE
8 ONLY
1
2
1
2
1
2
(BRIDGE)
10
8
12
10
8
6
14
6
4
18
4
ON
2
26
2
OFF
0
0
CLASS 2 WIRING
Audio
INPUTS
L
Extron
SSP 200
Surround Sound
Processor
50-60Hz
1
THRU
Audio
CLASS 2 WIRING
12
10
8
12
10
8
12
10
8
12
10
8
1
2
3
4
STANDBY
1
2
3
4
LIMITER/
14
6
14
6
14
6
14
6
G
PROTECT
18
4
4
4
4
1
1
1
1
26
2
2
2
2
0
0
0
0
100-240V
1.0A, 50-60Hz
1
2
3
4
1 2 3 4
XPA U 1004
SIGNAL
ATTENUATION
INPUTS
REMOTE
8Ω/4Ω OUTPUTS
Extron
XPA U 1004
Power Ampli er
CLASS 2 WIRING
1
2
STANDBY
1
2
G
INPUTS
REMOTE
8Ω/4Ω OUTPUTS
B
, on the previous page):
Extron
SF 26CT
CLASS 2 WIRING
10
10
10
8
12
8
12
8
1
2
3
4
STANDBY
1
2
3
4
6
14
6
14
6
G
Two-Way Ceiling Speakers
4
4
4
1
1
1
2
2
2
0
0
0
2
3
4
ATTENUATION
INPUTS
REMOTE
8Ω/4Ω OUTPUTS
Audio
R
1 (LF)
2 (RF)
3 (C)
4 (SUB)
5 (LS)
6 (RS)
7
8
9
(MIX)
10
5
RS-232
RESET
2
3
4
Tx
Rx G
LAN
SSP 200
DMP EXP
HDMI
Extron
SM 28
Speakers
Extron
SM 26
Speakers
H
). Refer to
LHF
RHF
LHB
RHB
HDMI Source
LF
C
RF
Extron
Extron
Extron
LS
RS
Extron
Extron
E
).
D
). The default baud rate is 9600.
figure 3
,
B
, on the next page).
A
, on the previous page).
Audio

Advertisement

loading
Need help?

Need help?

Do you have a question about the SSP 200 and is the answer not in the manual?

Questions and answers