Equipment Configuration Setting - Mitsubishi Electric MR-J5D-G User Manual

Ac servo system
Hide thumbs Also See for MR-J5D-G:
Table of Contents

Advertisement

5.
To operate the servo motor, input the motor speed and acceleration/deceleration time constants, then click "Forward
CCW" or "Reverse CW". The servo motor operates only while the button is being clicked. Give a low speed command at
first and check the operation status.
6.
After the test operation is complete, turn off the power and "OFF (down)" the test operation select switch (SW3-1).

Equipment configuration setting

Set the servo parameters for each function according to the equipment configuration. For details, refer to the following
manual.
MR-J5 User's Manual (Function)
Item
Rotation/travel direction selection
Stroke limit function
In-position setting
Forced stop deceleration function
Vertical axis freefall prevention function
Description
To change the rotation/travel direction (POL), change the servo parameter.
Limit switches can be used to limit travel intervals of the servo motor.
Configure the settings according to the connection method of the limit switch.
Positioning completion status can be checked with in-position. Set this as
necessary.
Stops the servo motor at EM2 (Forced stop 2) off. Perform settings such as
the deceleration time constant.
For vertical axes, this function pulls up the shaft slightly. When using a servo
motor with an electromagnetic brake for a vertical axis, perform settings as
required.
4.1 Turning on drive unit for the first time
4
4 STARTUP
49

Advertisement

Table of Contents
loading

Table of Contents