Mitsubishi Electric MR-J5D-G User Manual page 39

Ac servo system
Hide thumbs Also See for MR-J5D-G:
Table of Contents

Advertisement

Test operation select switch (SW3-1)
Turning "ON (up)" the test operation select switch enables the test operation mode. In the test operation mode, functions such
as JOG operation, positioning operation, and machine analyzer are available using MR Configurator2.
Page 53 Test operation
Disabling control axis switches (SW3-2, SW3-3, and SW3-4)
Turning "ON (up)" the disabling control axis switch disables the corresponding servo motor. The servo motor will become in
3
the disabled-axis state and will not be recognized by the controller.
Rotary switches (SW1/SW2)
The IP address can be set with the rotary switches (SW1/SW2) of the drive unit. SW1 indicates an upper digit and SW2
indicates a lower digit of a hexadecimal. The rotary switches are set to 01h when shipped from the factory.
To apply the settings of the rotary switches, set "0" (the rotary switch is used.) in [Pr. NPA01 IP address setting]. To set the IP
address without using the rotary switches, set them to 0 and use an engineering tool.
For how to set IP addresses, refer to "IP address setting function" in the following manual.
MR-J5-G/MR-J5W-G User's Manual (Communication Function)
3 STRUCTURE
37
3.2 Switch setting and display of the drive unit

Advertisement