● Press and hold down the button on the
right of the electronic card.
● Check the nozzle's filling position.
If the first filling position is not correct:
● Take the sampling device out of the lid
as described in "Replacing the chain
and sprocket" and turn over.
● Change the position of the limit switch
so that the filling nozzle is exactly on the
marking for the first filling position.
● Re-assemble the sampling device.
● Check the nozzle's first filling position again as described above.
7821-9001-005
01. October 2019
- The filling nozzle travels to position
41.
- The deviation may not be more than +/- 1.5 mm.
Warning!
Danger from automatic start
The conveyor chain can start to move when work is being carried out.
There is a risk of crushing and electric shock.
► Disconnect the cable from the power supply before starting the work.
- The limit switch is accessible.
Inspections and preventive maintenance
Maintenance
79 / 100