● Take the hose out of the housing cover.
● Insert a new hose in the housing cover.
● Screw the housing cover onto the hose pump.
● Reconnect the hoses to the outside of the hose pump.
The pump can now be used again.
7821-9001-005
01. October 2019
Attention!
Not fitting the housing cover properly can damage
the hose or cause fluctuation of the pump output.
► Make sure that the housing cover is positioned
correctly between the guide marks (x)!
- The housing cover must be flush
Note
After replacing the hose, reset the sample quantities required on the unit and
carry out a trial run.
Inspections and preventive maintenance
x
Maintenance
75 / 100