3.12 Smart Tamp Sensor Installation

The smart tamp sensor comes with all the needed hardware for installation. Start by
removing the back cover from the applicator using a 3mm hex wrench. Remove the M6
socket head screw from the inboard side of the tamp adapter plate. Place the smart tamp
sensor bracket in place and reinstall the M6 screw. Ensure that the angle of the bracket is
installed as shown for proper operation. With the tamp air cylinder extended, route and
secure the sensor cable along the air tubing through the baseplate to the rear of the
applicator. Place the four conductor connector through the grommeted hole on the
electrical module. Locating the J6 / SS connector on the pc board, plug the sensor in.
Coil up any excess cable and store inside the electronics module. Replace the back cover
and reconnect any cables disconnected during removal. Push the tamp pad back to the
tamp home position and check for any interference or pinch points that may damage the
sensor or cable.
SMART TAMP
SENSOR
RIGHT HAND
CONFIGURATION
If a left hand configuration is desired, remove the two screws attaching the sensor to the
bracket and reassemble as shown. The bracket/sensor assembly will attach to the tamp
adapter plate as indicated.
Before attempting to service machinery, the machine must be turned
off and the power and air locked out.
LEFT HAND
CONFIGURATION