ID Technology 252 Operator / Technical Manual page 156

Table of Contents

Advertisement

Figure 26: Installation Instructions, 62130 Main Air Cutoff Assembly
4
D
C
THE SPACER CLAMP. THE SPACER CLAMP ATTACHES TO
GROOVES IN THE FILTER REGULATOR BODY. (SHOWN BELOW)
B
SPACER CLAMPS HERE ON THE
FILTER REGULATOR. (BOTH SIDES)
THE INFORMATION
A
CONTAINED IN THIS
DRAWING IS THE SOLE
PROPERTY OF I D
TECHNOLOGY.
REPRODUCTION IN PART OR
WHOLE WITHOUT THE
WRITTEN PERMISSION OF ID
TECHNOLOGY IS
PROHIBITED.
4
3
EXISTING FILTER REGULATOR ASSEMBLY 62120
1)
REMOVE QUICK
DISCONNECT FITTING.
REPLACE THE QUICK DISCONNECT FITTING WITH
ATTACH THE AIR CUTOFF VALVE
TO THE SPACER CLAMP. (SHOWN BELOW)
SPACER CLAMPS HERE ON THE
AIR CUTOFF VALVE. (BOTH SIDES)
DETAIL A
3
2
COMPLETED ASSEMBLY OF THE FILTER
REGULATOR AND THE AIR CUTOFF ASSEMBLY.
FILTER REGULATOR ASSEMBLY
SPACER CLAMP
AIR CUTOFF VALVE
QUICK DISCONNECT FITTING
A
2)
4)
APPLY THREAD TAPE TO THE THREADS ON
THE QUICK DISCONNECT FITTING. THREAD THE
FITTING INTO THE AIR CUTOFF VALVE.
3)
DRAWN
menmi
CHECKED
QA
MFG
STANDARD
TOLERANCE
APPROVED
.00
 02
.000
 005
ANGLE
 1 
2
40
Label Printer/Applicator
Operators/Technical Manual
1
8/14/2008
2051 FRANKLIN DR.
FORT WORTH, TX 76106
TITLE
MAIN AIR CUTOFF INSTALLATION
SIZE
DWG NO
REV
C
62130
SCALE
SHEET 1 OF 1
1
Model 252
D
C
B
A

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for ID Technology 252

Table of Contents