Intertec Data Systems CP MULTITHERM DC.A Operating Instructions Manual

Intertec Data Systems CP MULTITHERM DC.A Operating Instructions Manual

Advertisement

Quick Links

Operating Instructions
CP MULTITHERM DC.A
HOM225650059Ien-3 • 10/02/2020

Advertisement

Table of Contents
loading

Summary of Contents for Intertec Data Systems CP MULTITHERM DC.A

  • Page 1 Operating Instructions CP MULTITHERM DC.A HOM225650059Ien-3 • 10/02/2020...
  • Page 2: Table Of Contents

    www.intertec.info Table of contents 1 General .................................. 3 2 Use ...................................  3 3 Special conditions for safe use.......................... 3 4 Explanation of symbols for warnings and signal words .................. 3 5 Safety information .............................. 4 6 Installation accessories ............................ 4 7 Technical Data ................................
  • Page 3: General

    Operating Instructions CP MULTITHERM DC.A General GB 50257-2014: Code for construction and acceptance of electric equipment on fire and explosion hazard elec- These operating instructions describe the safe and trical equipment installation engineering proper way to work with the device. The safety informa- GB 12476.2-2010: Electrical apparatus for use in the...
  • Page 4: Safety Information

    Operating Instructions CP MULTITHERM DC.A Piece Description CAUTION M 6x12 hexagon bolts T-head bolt type 28/15, M 6x15 NOTICE M6 flat square nut This sign is warning about a hazardous situation which, Washer shape A 6.4 if not heeded, may lead to slight, reversible injury.
  • Page 5: Installation

    Operating Instructions CP MULTITHERM DC.A Special voltages with corresponding power adjustment The connection cable must be permanently installed up and component selection are possible. to the inlet into the on-site junction box, taking the per- missible bending radius = 5 x outer diameter into consid- Profile type "N"...
  • Page 6 Operating Instructions CP MULTITHERM DC.A short-circuit protection. When using a heater without in- tegrated thermostat, the fuse protection can be selected according to the cross-section of the supply cable. Additional equipotential bonding is required. The ter- minal block designated for this purpose has the ground sign.
  • Page 7: Commissioning

    Operating Instructions CP MULTITHERM DC.A Repairs may only be carried out by the manufacturer in the factory. All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise. In the dust Ex area, the applicable requirements of GB Terminal box 3836.13-2013 must be complied with.
  • Page 8: Declaration Of Conformity

    Operating Instructions CP MULTITHERM DC.A • Sort other components according to their material properties and dispose of them. NOTICE Environmental damage may be caused if dis- Dipl.-Ing. Martin Hess, Managing Director posed of incorrectly! Electrical scrap and electronics components are subject...
  • Page 9 Operating Instructions CP MULTITHERM DC.A HOM225650059Ien-3 Page 9 / 12 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...
  • Page 10 Operating Instructions CP MULTITHERM DC.A Page 10 / 12 HOM225650059Ien-3 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...
  • Page 11 Operating Instructions CP MULTITHERM DC.A HOM225650059Ien-3 Page 11 / 12 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...
  • Page 12 Operating Instructions CP MULTITHERM DC.A Page 12 / 12 HOM225650059Ien-3 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...