CS351 | 3609929B45/2014-09
The maximum torque at the bol-
ted connections of the terminals
at XDN1 must not exceed 0.3
Nm.
CAUTION
Risk of damage to persons and pro-
perty!
The user is obliged to maintain the
system-specific requirements for an
emergency OFF system.
When using external power supply
contactors in higher-level emergency
OFF circuits, observe the restarting
time of 10 seconds for single swit-
ching and 30 seconds for repeated
switching.
Check that the emergency OFF cir-
cuits are functioning properly before
commissioning the tightening system.
Observe the local, system-specific re-
gulations and requirements; proper
use of tools, lifting, and transport
equipment; as well as the pertinent
standards, provisions, and occupatio-
nal safety regulations.
Bosch Rexroth AG
Product description
CAUTION
Risk of damage to persons and pro-
perty!
Dangerous shock currents due to inade-
quate PE wire connections!
Protective conductor connections
must not be affected by mechanical,
chemical, or electrochemical influen-
ces. The connection must be perma-
nent.
NOTE
The voltage circuits at terminal XDN1
are safely isolated from the power
supply circuits (safe isolation in ac-
cordance with EN50178). The requi-
rements for safe isolation of electric
circuits must be observed when using
the connection options on this termi-
nal.