9
Maintenance and re-
pair
DANGER
Electrical voltages!
Electrocution
Do not carry out maintenance work on
the tightening channel unless the
Compact System has been switched
off and the power plug disconnected.
Protect the system from being swit-
ched on again.
9.1
Repair
Reset function of the Compact System
Fig. 35:
Reset button
A software reset is generated if the reset
button is briefly pressed, i.e. for < 1 second.
The controller is reset once the button is re-
leased.
A hardware reset is generated if the reset
button is pressed for a long period, i.e. for >
3 seconds. The controller and servo ampli-
fier are reset once the button is released.
Bosch Rexroth AG

Maintenance and repair

Reboot function of the computer unit
If you have to reset the operating system be-
cause it is blocked by a running program or
has crashed, push and hold the reboot but-
ton (see Fig. 36).
Once you release the button, the operating
system is restarted.
Reboot
Fig. 36:
Reboot button
Windows repair
If the Windows operating system of the in-
tegrated computer unit fails to run or boot
properly, it can be returned to its state on
delivery using an USB recovery stick.
The USB recovery stick is not included in
the delivery of the Compact System and
must be ordered separately.
For the Windows license key required for
repair, refer to the small sticker on the cover
of the Compact System directly below the
type label.
For instructions on this Windows repair, re-
fer to the documentation supplied with the
USB recovery stick.