Bosch Rexroth CS351 Manual page 9

Hide thumbs Also See for Rexroth CS351:
Table of Contents

Advertisement

CS351 | 3609929B45/2014-09
DANGER
Inadequate emergency OFF equip-
ment!
Danger to life through electrical or me-
chanical forces
The user is responsible for determin-
ing the need for an emergency OFF
system, its implementation, and the
risk analysis therefor! Make sure the
emergency OFF equipment is acces-
sible and effective. Releasing the
emergency OFF equipment must not
result in an uncontrolled system re-
start!
Check the function of the emergency
OFF equipment before switching the
system on.
Only operate the Compact System in
grounded networks. Operation in non-
grounded networks (IT network) is not per-
mitted, as clearance and creepage dis-
tances in the system may be overloaded.
Here, protective grounding is the permissi-
ble protective measure in accordance with
EN 50178. The input cable to the Compact
System must have a PE wire.
Ensure that there is potential equalization
between the workpiece and the tightening
spindle, as well as the carrier plate therefor,
so that potential equalization is ensured for
all system components.
Protect the system from short circuits in the
connector cables with a fuse provided by
the customer.
After switching the device off, wait 10 sec-
onds before turning it back on.
Bosch Rexroth AG
General safety instructions
Observe the discharging time (at least 90
seconds after disconnecting the system
from the network) before working on the
power supply connections.
During cleaning
Cover all openings with appropriate protec-
tive devices to prevent detergent from get-
ting into the system.
Never use solvents or aggressive deter-
gents. Only clean the product using a
slightly damp, lint-free cloth. Only use water
to do this and, if necessary, a mild deter-
gent.
Do not use a high-pressure cleaner for
cleaning.
During maintenance and repair
Perform the prescribed maintenance work
at the intervals specified in the instruction
manual.
Make sure that no lines, connectors or com-
ponents are disconnected while the system
is under pressure and energized. Protect
the system from being switched on again.
61/108

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth cc-cs351

Table of Contents