X1N power supply connection
interface
The compact system is delivered with an
EU power supply connection and power
plug with screw terminals. The power sup-
ply connection cable can be unscrewed at
the connection plug and assembled as
desired.
A connection cable for the American market
is available, but must be ordered separately.
NOTE
Damage due to use of non-original
parts!
Damage to the Compact System
Only use power supply connection
cables from Rexroth.
The Rexroth product range includes
suitable cables. Observe local regula-
tions in this regard.
1
PE
Fig. 4:
Connection assignment of the power
supply connection plug
Tab.2: X1N pin assignment
Pin
1
2
3
PE
2
3
CS351 | 3609929B45/2014-09
Description/
Signal
function
L1
L1 power supply
connection
N
Power supply
connection
neutral
n.c.
-
PE
Leading PE wire PE potential
Voltage/
current
230 V
/5 A,
AC
120V
/10A
AC
230 V
/5 A,
AC
120V
/10A
AC