Bosch Rexroth AG
Product description
Hex coding switch
On networked systems (sibracks, system
boxes or compact systems), the valid
address must be set on the hex coding
switch before commissioning. For this pur-
pose, the address is determined on the in-
ternal bus.
This setting ensures a clear identification of
each tightening channel. Values from 0 - F
(address 0 - 15) can be entered. After ha-
ving entered the address, you must reset or
restart the system.
8
0
Fig. 22:
Setting the address of the Compact
System
NOTE
Never enter two identical addresses (sub-
rack, system box or compact system) in
the system bus. The address of a system
bus consumer must always be unique.
XDAc2
address
CS351 | 3609929B45/2014-09
4.2
Further interfaces of the
variant with integrated
computer unit
The integrated computer unit of the
CS351E-G+ and CS351S-G+ variants
features the following additional interfaces..
Slot for a Micro-SD memory card
(X6MSD2)
The slot with SDIO interface (Secure Digital
Input Output) is designed for an SD me-
mory card of size 15 x 11 x 1mm (length x
width x height) functioning according to
SDHC standard.. These cards have a sto-
rage capacity of up to 32 GB.
NOTE
If it is inserted improperly, the me-
mory card may get lost.
Carefully insert the card in the slot,
holding it straight and with its pins
pointing forward. The product label
(front of the card) must be uppermost.
Particularly when starting insertion,
make sure that you position the card
in the guide provided and not in the
gap between the card guide and the
front panel.
Push the memory card into the slot
until you feel it reach the end stop. Do
not push it any further.