Dynamic Teach - Banner DF-G1 Install Sheet

Expert fiber amplifier advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Hide thumbs Also See for DF-G1:
Table of Contents

Advertisement

DF-G1 - Expert Fiber Amplifier Install Sheet

Dynamic TEACH

• Teaches on-the-fly
• Establishes a single switching threshold
• Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual sensing conditions, taking multiple samples of
the light and dark conditions and automatically setting the threshold at the optimum level (see Figure below).
The output ON and OFF conditions can be reversed using the LO/DO switch (see LO/DO Switch in
Dynamic TEACH and Manual Adjust
• Moves switching threshold value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press "+" to increase; press "-" to decrease
• GREEN display shows the switching threshold value
• 2 seconds after adjustment, GREEN display will flash 3 times to confirm
• Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled
when Auto Thresholds are ON
SET Button
0.04 seconds < "Click" < 0.8 seconds
Note: TEACH Selection must be programmed to dYn tcH (see
• Set Mode switch to ADJ
Enter Adjust
Mode
• Click the SET rocker button
Enter Dynamic
TEACH
Present ON
• Present ON and OFF conditions
and OFF Con-
ditions
• Click the SET rocker button
Exit Dynamic
TEACH
• Move Mode switch to RUN
Return to RUN
Mode
* See
Troubleshooting
on page 10 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH method
P/N 161275 Rev. A
For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com
Top Panel Interface
Darkest
(no signal)
Figure 3. Dynamic TEACH (Light Operate shown)
Remote Input
0.04 seconds < T < 0.8 seconds
Program Mode
No action required; sensor is ready for
Dynamic TEACH method
• Single-pulse remote input
T
• Present ON and OFF conditions
• Single-pulse remote input
T
No action required; sensor returns to
RUN mode automatically
www.bannerengineering.com - tel: 763-544-3164
on page 2).
Darkest Taught
Condition
Sensor positions
threshold midway
between taught conditions
Output OFF
Position
adjusted by
Manual Adjust
Result
on page 3 )
Display: Red - Signal Level; Green -
Threshold
Display: Flashes "dYn tch" then
holds on "1234 dYn"
Display: Red - Signal Level; Green -
Threshold
TEACH Accepted
Displays alternate "PASS" with % Min-
imum Difference*, Sensor returns to
Adjust mode
TEACH Unacceptable
Displays alternate "FAIL" with % Mini-
mum Difference*, Sensor returns to
Adjust mode
Display: Red - Signal Level; Green -
Threshold
Lightest Taught
Condition
Output ON
Most Light
(saturated
signal)
5